Comparison between IEEE and CIGRE thermal behaviour standards and measured temperature on a 132-kV overhead power line A Arroyo, P Castro, R Martinez, M Manana, A Madrazo, R Lecuna, ... Energies 8 (12), 13660-13671, 2015 | 81 | 2015 |
Thermal-fluid characterization of alternative liquids of power transformers: A numerical approach R Lecuna, F Delgado, A Ortiz, PB Castro, I Fernandez, CJ Renedo IEEE Transactions on Dielectrics and Electrical Insulation 22 (5), 2522-2529, 2015 | 61 | 2015 |
Study of different mathematical approaches in determining the dynamic rating of overhead power lines and a comparison with real time monitoring data P Castro, A Arroyo, R Martinez, M Manana, R Domingo, A Laso, R Lecuna Applied Thermal Engineering 111, 95-102, 2017 | 31 | 2017 |
Infrared temperature measurement sensors of overhead power conductors P Castro, R Lecuna, M Manana, MJ Martin, D Campo Sensors 20 (24), 7126, 2020 | 17 | 2020 |
Non-contact temperature measurement method for dynamic rating of overhead power lines. R Lecuna, P Castro, M Manana, A Laso, R Domingo, A Arroyo, R Martinez Electric Power Systems Research 185, 106392, 2020 | 13 | 2020 |
The use of computational fluid dynamics to study furnace effects in ITS-90 fixed points realizations P Castro, D del Campo, R Lecuna, CG Izquierdo Measurement 91, 703-706, 2016 | 3 | 2016 |
A comparison of mechanical and ultrasonic anemometers for ampacity thermal rating in overhead lines A Laso, M Manana, A Arroyo, A Gonzalez, R Lecuna RE&PQJ 14 (6), 2016 | 3 | 2016 |
Analysis of a Real Case of Ampacity Management in a 132 kV Network Integrating High Rates of Wind Energy. A Madrazo, A González, R Martínez, R Domingo, M Mañana, A Arroyo, ... RE&PQJ 13 (6), 2015 | 3 | 2015 |
Aprendizaje a través de supuestos reales (Retos) como metodología innovadora en la FP R Lecuna Tolosa | 1 | 2018 |
Infrared temperature measurement sensors of overhead power conductors PB Castro Alonso, R Lecuna Tolosa, M Mañana Canteli, ... MDPI, 2020 | | 2020 |
Non-contact temperature measurement method for dynamic rating of overhead power lines R Lecuna Tolosa, PB Castro Alonso, M Mañana Canteli, A Laso Pérez, ... Elsevier, 2020 | | 2020 |
Desarrollo de un prototipo y validación de método de medida sin contacto de parámetros característicos de líneas eléctricas R Lecuna Tolosa | | 2018 |
Methodology for the Low-Cost Optimisation of Small-Wind Turbines A Arroyo, M Manana, PB Castro, R Martinez, R Lecuna, J Carcedo Wind Turbines-Design, Control and Applications, 2016 | | 2016 |
The use of computational fluid dynamics to study furnace effects in ITS-90 fixed points realizations PB Castro Alonso, MD Campo Maldonado, R Lecuna Tolosa, ... Elsevier, 2016 | | 2016 |
A comparison of mechanical and ultrasonic anemometers for ampacity thermal rating in overhead lines A Laso Pérez, M Mañana Canteli, A Arroyo Gutiérrez, A González Diego, ... The European Association for the Development of Renewable Energies …, 2016 | | 2016 |
Methodology for the low-cost optimisation of small-wind turbines A Arroyo Gutiérrez, M Mañana Canteli, PB Castro Alonso, ... InTech, 2016 | | 2016 |
Analysis of a real case of ampacity management in a 132 kV network integrating high rates of wind energy A Madrazo Maza, A González, R Martínez Torre, R Domingo Fernández, ... European Association for the Development of Renewable Energies, Environment …, 2015 | | 2015 |
Metodología para el cálculo y predicción de la ampacidad en líneas eléctricas aéreas, según la elección de los emplazamientos críticos M Mañana Canteli, A Arroyo Gutiérrez, PB Castro Alonso, ... | | 2015 |
Thermal-fluid characterization of alternative liquids of power transformers: a numerical approach R Lecuna Tolosa, F Delgado San Román, A Ortiz Fernández, ... Institute of Electrical and Electronics Engineers, 2015 | | 2015 |