Analysis based on EU Regulation No 517/2014 of new HFC/HFO mixtures as alternatives of high GWP refrigerants in refrigeration and HVAC systems A Mota-Babiloni, J Navarro-Esbrí, Á Barragán-Cervera, F Molés, B Peris International journal of refrigeration 52, 21-31, 2015 | 237 | 2015 |
Drop-in energy performance evaluation of R1234yf and R1234ze (E) in a vapor compression system as R134a replacements A Mota-Babiloni, J Navarro-Esbrí, Á Barragán, F Molés, B Peris Applied Thermal Engineering 71 (1), 259-265, 2014 | 215 | 2014 |
Experimental analysis of R1234yf as a drop-in replacement for R134a in a vapor compression system J Navarro-Esbrí, JM Mendoza-Miranda, A Mota-Babiloni, ... International Journal of Refrigeration 36 (3), 870-880, 2013 | 197 | 2013 |
Experimental study of an ORC (organic Rankine cycle) for low grade waste heat recovery in a ceramic industry B Peris, J Navarro-Esbrí, F Molés, A Mota-Babiloni Energy 85, 534-542, 2015 | 175 | 2015 |
A review of refrigerant R1234ze (E) recent investigations A Mota-Babiloni, J Navarro-Esbrí, F Molés, ÁB Cervera, B Peris, G Verdú Applied Thermal Engineering 95, 211-222, 2016 | 150 | 2016 |
Commercial refrigeration–an overview of current status A Mota-Babiloni, J Navarro-Esbrí, Á Barragán-Cervera, F Molés, B Peris, ... International journal of refrigeration 57, 186-196, 2015 | 118 | 2015 |
Bottoming organic Rankine cycle configurations to increase Internal Combustion Engines power output from cooling water waste heat recovery B Peris, J Navarro-Esbrí, F Molés Applied Thermal Engineering 61 (2), 364-371, 2013 | 117 | 2013 |
Low GWP alternatives to HFC-245fa in Organic Rankine Cycles for low temperature heat recovery: HCFO-1233zd-E and HFO-1336mzz-Z F Molés, J Navarro-Esbrí, B Peris, A Mota-Babiloni, Á Barragán-Cervera, ... Applied Thermal Engineering 71 (1), 204-212, 2014 | 113 | 2014 |
Refrigerant R32 as lower GWP working fluid in residential air conditioning systems in Europe and the USA A Mota-Babiloni, J Navarro-Esbrí, P Makhnatch, F Molés Renewable and Sustainable Energy Reviews 80, 1031-1042, 2017 | 95 | 2017 |
Theoretical energy performance evaluation of different single stage vapour compression refrigeration configurations using R1234yf and R1234ze (E) as working fluids F Molés, J Navarro-Esbrí, B Peris, A Mota-Babiloni, Á Barragán-Cervera International Journal of Refrigeration 44, 141-150, 2014 | 93 | 2014 |
Experimental analysis of the internal heat exchanger influence on a vapour compression system performance working with R1234yf as a drop-in replacement for R134a J Navarro-Esbrí, F Moles, Á Barragán-Cervera Applied Thermal Engineering 59 (1-2), 153-161, 2013 | 93 | 2013 |
Experimental study of an R1234ze (E)/R134a mixture (R450A) as R134a replacement A Mota-Babiloni, J Navarro-Esbrí, Á Barragán-Cervera, F Molés, B Peris International Journal of Refrigeration 51, 52-58, 2015 | 92 | 2015 |
Theoretical comparison of low GWP alternatives for different refrigeration configurations taking R404A as baseline A Mota-Babiloni, J Navarro-Esbrí, Á Barragán, F Molés, B Peris International Journal of Refrigeration 44, 81-90, 2014 | 83 | 2014 |
Experimental characterization of an Organic Rankine Cycle (ORC) for micro-scale CHP applications B Peris, J Navarro-Esbrí, F Molés, JP Martí, A Mota-Babiloni Applied Thermal Engineering 79, 1-8, 2015 | 79 | 2015 |
Thermodynamic analysis of a combined organic Rankine cycle and vapor compression cycle system activated with low temperature heat sources using low GWP fluids F Molés, J Navarro-Esbrí, B Peris, A Mota-Babiloni, KK Kontomaris Applied Thermal Engineering 87, 444-453, 2015 | 76 | 2015 |
Performance evaluation of an Organic Rankine Cycle (ORC) for power applications from low grade heat sources B Peris, J Navarro-Esbrí, F Molés, R Collado, A Mota-Babiloni Applied Thermal Engineering 75, 763-769, 2015 | 73 | 2015 |
Drop-in analysis of an internal heat exchanger in a vapour compression system using R1234ze (E) and R450A as alternatives for R134a A Mota-Babiloni, J Navarro-Esbrí, Á Barragán-Cervera, F Molés, B Peris Energy 90, 1636-1644, 2015 | 72 | 2015 |
Evaluation of R448A and R450A as low-GWP alternatives for R404A and R134a using a micro-fin tube evaporator model JM Mendoza-Miranda, A Mota-Babiloni, J Navarro-Esbrí Applied Thermal Engineering 98, 330-339, 2016 | 66 | 2016 |
Experimental evaluation of R448A as R404A lower-GWP alternative in refrigeration systems A Mota-Babiloni, J Navarro-Esbrí, B Peris, F Molés, G Verdú Energy Conversion and Management 105, 756-762, 2015 | 66 | 2015 |
A simplified black-box model oriented to chilled water temperature control in a variable speed vapour compression system JA Romero, J Navarro-Esbrí, JM Belman-Flores Applied Thermal Engineering 31 (2-3), 329-335, 2011 | 65 | 2011 |