Seguir
María José Palomo
María José Palomo
Profesora de Industriales, Universidad Politécnica de Valencia
Dirección de correo verificada de iqn.upv.es - Página principal
Título
Citado por
Citado por
Año
Dynamic forces produced by swinging bells
S Ivorra, MJ Palomo, G Verdú, A Zasso
Meccanica 41, 47-62, 2006
392006
Modeling condensation heat transfer on a horizontal finned tube in the presence of noncondensable gases
LE Herranz, JL Muñoz-Cobo, MJ Palomo
Nuclear engineering and design 201 (2-3), 273-288, 2000
302000
Forsmark 1&2 Stability Benchmark. Time series analysis methods for oscillations during BWR operation. Final Report
G Verdu, D Ginestar, JL Muñoz-Cobo, J Navarro-Esbri, MJ Palomo, ...
NEA/NSC/DOC (2001) 2, 2001
172001
Magnetic field generated by the loops used in traffic control systems
A Mocholí-Salcedo, JH Arroyo-Núñez, VM Milián-Sánchez, ...
IEEE Transactions on Intelligent Transportation Systems 18 (8), 2126-2136, 2016
152016
Forsmark 1&2 Stability Benchmark. Time series analysis methods for oscillations during BWR operation
G Verdú, D Ginestar, JL Munoz-Cobo, J Navarro-Esbri, MJ Palomo, ...
Nuclear Science, Final Report, NEA/NSC/DOC 2, 2001
102001
Dynamic behaviour of a belfry caused by the swinging bells
S Ivorra, MJ Palomo, G Verdú
International journal of solids and structures 42 (5-6), 1669-1680, 2005
92005
Analysis of pressure signals using a singular system analysis (SSA) methodology
MJ Palomo, R Sanchis, G Verdu, D Ginestar
Progress in Nuclear Energy 43 (1-4), 329-336, 2003
82003
Modelling the influence of aerosol deposition onto horizontal finned tubes on heat transfer under cross-flow condensing conditions
LE Herranz, JL Muñoz-Cobo, MJ Palomo
Experimental thermal and fluid science 26 (2-4), 189-195, 2002
62002
Predictive modeling of steam condensation onto finned tubes in the presence of noncondensable gases for passive safety reactor containment heat exchangers
JL Muñoz-Cobo, MJ Palomo, LE Herranz
Nuclear technology 134 (1), 23-36, 2001
52001
FORSMARKS 1 AND 2 Stability benchmark-Final Problem Specifications
G Verdu, MJ Palomo, A Escriva, D Ginestar
NEANSC/DOC (98) 2, 1998
51998
Forsmark 1 & 2 Boiling Water Reactor Stability Benchmark
G Verdú, D Ginestar, JL Muñoz-Cobo, J Navarro, MJ Palomo, P Lansaker, ...
Time Series Methods for Oscillations during BWR Operation—Final Report, 2001
42001
Theoretical support of heat exchanger experiments of the EU-CONGA Project
LE Herranz, J Lopez Jimenez, JL Munoz-Cobo, MJ Palomo
Ciemat, 1999
31999
A first approach to study an 18th century belltower
S Ivorra, MJ Palomo, G Verdú, F Pallarés
Structural Analysis of Historical Constructions-2 Volume Set: Possibilities …, 2018
22018
EXPERIENCES IN DEVELOPING AND APPLYING A NEW METHODOLOGY IN MASTER’S DEGREE
T Barrachina, B Juste, R Miró, R Sanchis, MJ Palomo, A Escrivá, ...
EDULEARN17 Proceedings, 6394-6399, 2017
2017
Project development: testing of heat exchange of cooling system and cleaning fuel pool of NPP Cofrentes; Desarrollo del proyecto Prueba de Intercambio Termico del Sistema de …
B Lopez, JI Vaquer, M Mota, S Reyes, M Palomo, G Ruiz, C Rebollo
2012
Desarrollo del proyecto “Pruebas de Intercambio Térmico del Sistema de Enfriamiento y Limpieza de la Piscina de Combustible (G41)” de Central Nuclear de Cofrentes
B López, JI Vaquer, M Mota, S Reyes, MJ Palomo-Anaya, G Ruiz, ...
Grupo Senda, 2012
2012
Project development: testing of heat exchange of cooling system and cleaning fuel pool of NPP Cofrentes
B Lopez, JI Vaquer, M Mota, S Reyes, M Palomo, G Ruiz, C Rebollo
38 Annual Meeting of Spanish Nuclear Society, Oct 17-19, 2012, Caceres, Spain, 2012
2012
Preventive maintenance instrumentation results in Spanish nuclear power plants
MJ Palomo Anaya, G Verdu Martin, A Arnaldos Gonzalvez, MC Nieva
2011
Results of automatic system implementation for Cofrentes power plant detection system LPRM inspection execution
M Palomo, M Urrea, M Curiel, A Arnaldos
2011
Sipping machine control system new design to perform integrity of nuclear fuel test in Cofrentes power plant
M Palomo, M Urrea, M Curiel, A Arnaldos
2011
El sistema no puede realizar la operación en estos momentos. Inténtalo de nuevo más tarde.
Artículos 1–20