Radiochromic film for medical radiation dosimetry MJ Butson, KN Peter, T Cheung, P Metcalfe Materials Science and Engineering: R: Reports 41 (3-5), 61-120, 2003 | 487 | 2003 |
The potential for an enhanced role for MRI in radiation-therapy treatment planning P Metcalfe, GP Liney, L Holloway, A Walker, M Barton, GP Delaney, ... Technology in cancer research & treatment 12 (5), 429-446, 2013 | 236 | 2013 |
The physics of radiotherapy X-rays from linear accelerators P Metcalfe, P Hoban, T Kron Medical Physics Pub., 1997 | 211 | 1997 |
A new radiotherapy surface dose detector: the MOSFET MJ Butson, A Rozenfeld, JN Mathur, M Carolan, TPY Wong, PE Metcalfe Medical physics 23 (5), 655-658, 1996 | 195 | 1996 |
The physics of radiotherapy x-rays and electrons PE Metcalfe, T Kron, P Hoban | 183 | 2007 |
A review of methods of analysis in contouring studies for radiation oncology MG Jameson, LC Holloway, PJ Vial, SK Vinod, PE Metcalfe Journal of medical imaging and radiation oncology 54 (5), 401-410, 2010 | 172 | 2010 |
MRI distortion: considerations for MRI based radiotherapy treatment planning A Walker, G Liney, P Metcalfe, L Holloway Australasian physical & engineering sciences in medicine 37, 103-113, 2014 | 160 | 2014 |
Measurement of radiotherapy x‐ray skin dose on a chest wall phantom KY Quach, J Morales, MJ Butson, AB Rosenfeld, PE Metcalfe Medical physics 27 (7), 1676-1680, 2000 | 160 | 2000 |
Future of medical physics: real‐time MRI‐guided proton therapy BM Oborn, S Dowdell, PE Metcalfe, S Crozier, R Mohan, PJ Keall Medical physics 44 (8), e77-e90, 2017 | 151 | 2017 |
Effects on skin dose from unwanted air gaps under bolus in photon beam radiotherapy MJ Butson, T Cheung, P Yu, P Metcalfe Radiation Measurements 32 (3), 201-204, 2000 | 131 | 2000 |
Directional dependence in film dosimetry: radiographic and radiochromic film N Suchowerska, P Hoban, M Butson, A Davison, P Metcalfe Physics in Medicine & Biology 46 (5), 1391, 2001 | 128 | 2001 |
X‐ray surface dose measurements using TLD extrapolation T Kron, A Elliot, T Wong, G Showell, B Clubb, P Metcalfe Medical physics 20 (3), 703-711, 1993 | 126 | 1993 |
Comparison of prostate IMRT and VMAT biologically optimised treatment plans N Hardcastle, WA Tomé, K Foo, A Miller, M Carolan, P Metcalfe Medical Dosimetry 36 (3), 292-298, 2011 | 104 | 2011 |
In vivo verification of superficial dose for head and neck treatments using intensity‐modulated techniques ZY Qi, XW Deng, SM Huang, L Zhang, ZC He, X Allen Li, I Kwan, M Lerch, ... Medical physics 36 (1), 59-70, 2009 | 99 | 2009 |
Characterization of a novel two dimensional diode array the “magic plate” as a radiation detector for radiation therapy treatment JHD Wong, I Fuduli, M Carolan, M Petasecca, MLF Lerch, ... Medical physics 39 (5), 2544-2558, 2012 | 97 | 2012 |
Investigation of the tissue equivalence of gells used for NMR dosimetry T Kron, P Metcalfe, J Pope Physics in Medicine & Biology 38 (1), 139, 1993 | 89 | 1993 |
Proton beam deflection in MRI fields: implications for MRI‐guided proton therapy BM Oborn, S Dowdell, PE Metcalfe, S Crozier, R Mohan, PJ Keall Medical physics 42 (5), 2113-2124, 2015 | 88 | 2015 |
Monte Carlo characterization of skin doses in 6 MV transverse field MRI‐linac systems: effect of field size, surface orientation, magnetic field strength, and exit bolus BM Oborn, PE Metcalfe, MJ Butson, AB Rosenfeld Medical Physics 37 (10), 5208-5217, 2010 | 88 | 2010 |
Radiochromic film dosimetry and its applications in radiotherapy M Williams, P Metcalfe AIP Conference Proceedings 1345 (1), 75-99, 2011 | 87 | 2011 |
High resolution entry and exit Monte Carlo dose calculations from a linear accelerator 6 MV beam under the influence of transverse magnetic fields BM Oborn, PE Metcalfe, MJ Butson, AB Rosenfeld Medical Physics 36 (8), 3549-3559, 2009 | 87 | 2009 |