Seguir
Hans Martin Kjer
Hans Martin Kjer
Dirección de correo verificada de dtu.dk
Título
Citado por
Citado por
Año
Evaluation of surface registration algorithms for PET motion correction
HM Kjer, J Wilm
Technical University of Denmark, DTU, DK-2800 Kgs. Lyngby, Denmark, 2010
1222010
A voxel-based investigation for MRI-only radiotherapy of the brain using ultra short echo times
JM Edmund, HM Kjer, K Van Leemput, RH Hansen, JAL Andersen, ...
Physics in Medicine & Biology 59 (23), 7501, 2014
1182014
Axon morphology is modulated by the local environment and impacts the noninvasive investigation of its structure–function relationship
M Andersson, HM Kjer, J Rafael-Patino, A Pacureanu, B Pakkenberg, ...
Proceedings of the National Academy of Sciences 117 (52), 33649-33659, 2020
702020
A multiscale imaging and modelling dataset of the human inner ear
N Gerber, M Reyes, L Barazzetti, HM Kjer, S Vera, M Stauber, P Mistrik, ...
Scientific data 4 (1), 1-12, 2017
462017
Iterative closest point
J Wilm, HM Kjer
MATLAB Central, 2013
272013
Patient-specific estimation of detailed cochlear shape from clinical CT images
HM Kjer, J Fagertun, W Wimmer, N Gerber, S Vera, L Barazzetti, ...
International journal of computer assisted radiology and surgery 13, 389-396, 2018
232018
Patient-specific simulation of implant placement and function for cochlear implantation surgery planning
M Ceresa, N Mangado Lopez, H Dejea Velardo, N Carranza Herrezuelo, ...
Medical Image Computing and Computer-Assisted Intervention–MICCAI 2014: 17th …, 2014
232014
Automatic model generation framework for computational simulation of cochlear implantation
N Mangado, M Ceresa, N Duchateau, HM Kjer, S Vera, H Dejea Velardo, ...
Annals of biomedical engineering 44, 2453-2463, 2016
202016
Fast super resolution ultrasound imaging using the erythrocytes
JA Jensen, M Schou, SB Andersen, SB Søgaard, CM Sørensen, ...
Medical Imaging 2022: Ultrasonic Imaging and Tomography 12038, 79-84, 2022
182022
Free-form image registration of human cochlear μCT data using skeleton similarity as anatomical prior
HM Kjer, J Fagertun, S Vera, D Gil, MAG Ballester, RR Paulsen
Pattern Recognition Letters 76, 76-82, 2016
172016
Evaluation of 2D super-resolution ultrasound imaging of the rat renal vasculature using ex vivo micro-computed tomography
SB Andersen, I Taghavi, HM Kjer, SB Søgaard, C Gundlach, VA Dahl, ...
Scientific reports 11 (1), 24335, 2021
152021
Does powder averaging remove dispersion bias in diffusion MRI diameter estimates within real 3D axonal architectures?
M Andersson, M Pizzolato, HM Kjer, KF Skodborg, H Lundell, TB Dyrby
NeuroImage 248, 118718, 2022
142022
VirtualTable: a projection augmented reality game
A Dal Corso, M Olsen, KH Steenstrup, J Wilm, S Jensen, RR Paulsen, ...
SIGGRAPH Asia 2015 Posters, 1-1, 2015
122015
Shape modelling of the inner ear from micro-ct data
HM Kjer, J Fagertun, S Vera, MAG Ballester, RR Paulsen
Symposium on statistical shape models and applications (Shape 2014), 21, 2014
102014
Modelling of the Human Inner Ear Anatomy and Variability for Cochlear Implant Applications
HM Kjer
Technical University of Denmark, 2016
92016
Predicting Detailed Inner Ear Anatomy from Pre-Oppreoperational CT for cochlear implant surgery
HM Kjer, S Vera, J Fagertun, F Pérez, J Herrero, MÁG Ballester, ...
International Journal of Computer Assisted Radiology and Surgery 10 …, 2015
82015
Cochlear implant electrode localization in post-operative CT using a spherical measure
B Braithwaite, HM Kjer, J Fagertun, MAG Ballester, A Dhanasingh, ...
2016 IEEE 13th International Symposium on Biomedical Imaging (ISBI), 1329-1333, 2016
72016
Random walks with shape prior for cochlea segmentation in ex vivo μCT.
HM Kjer, G Piella, M Ceresa, G Ballester
International journal of computer assisted radiology and surgery 11 (9 …, 2016
72016
Joint CT reconstruction and segmentation with discriminative dictionary learning
Y Dong, PC Hansen, HM Kjer
IEEE Transactions on Computational Imaging 4 (4), 528-536, 2018
62018
Random walks with statistical shape prior for cochlea and inner ear segmentation in micro-CT images
E Ruiz Pujadas, G Piella, HM Kjer, MA González Ballester
Machine Vision and Applications 29, 405-414, 2018
62018
El sistema no puede realizar la operación en estos momentos. Inténtalo de nuevo más tarde.
Artículos 1–20