Follow
Jose Antonio Castillo Torrres
Jose Antonio Castillo Torrres
Postdoctoral Research Fellow, Department of Architecture, Sonora University
Verified email at ier.unam.mx - Homepage
Title
Cited by
Cited by
Year
Experimental study on natural ventilation of a room with a windward window and different windexchangers
MV Cruz-Salas, JA Castillo, G Huelsz
Energy and Buildings 84, 458-465, 2014
422014
A methodology to evaluate the indoor natural ventilation in hot climates: Heat Balance Index
JA Castillo, G Huelsz
Building and Environment 114, 366-373, 2017
322017
Natural ventilation of an isolated generic building with a windward window and different windexchangers: CFD validation, sensitivity study and performance analysis
JA Castillo, G Huelsz, T van Hooff, B Blocken
Building Simulation 12, 475-488, 2019
292019
Effect of windexchanger duct cross-section area and geometry on the room airflow distribution
MV Cruz-Salas, JA Castillo, G Huelsz
Journal of Wind Engineering and Industrial Aerodynamics 179, 514-523, 2018
272018
Flow generated by a thermal plume in a cooled-ceiling system
LP Thomas, BM Marino, R Tovar, JA Castillo
Energy and Buildings 43 (10), 2727-2736, 2011
192011
Transient cooling of a room with a chilled ceiling
JA Castillo, R Tovar
Solar Energy 86 (4), 1029-1036, 2012
162012
Energía y confort en edificaciones
J Rojas, G Huelsz, R Tovar, G Barrios, A Lira-Oliver, A Castillo
Revista Digital Universitaria 11 (10), 5, 2010
102010
Uso de sistemas pasivos de climatización en la zona de Temixco Morelos con clima cálido semi-húmedo
JA Castillo, A Lira-Oliver, JJ Muñoz, CÁ Ramírez, SN Juárez, J Rojas, ...
Memorias del XXXV SNES, 183-8, 2011
92011
Natural ventilation by windexchangers in a building with a window in prevailing winds: design guidelines
JA Castillo, MV Cruz-Salas, G Huelsz
International Journal of Ventilation 16 (1), 1-14, 2017
82017
Heat transfer by natural convection and radiation in three dimensional differentially heated tall cavities
P Hernández-Castillo, JA Castillo, G Huelsz
Case Studies in Thermal Engineering 40, 102529, 2022
62022
Convection generated by a small heat source in a box with a cooled upper contour at constant temperature
LP Thomas, BM Marino, R Tovar, JA Castillo
Journal of Physics: Conference Series 296 (1), 012022, 2011
62011
Optimización energética para el aprovechamiento de ventilación natural en edificaciones en climas cálidos del Ecuador (tesis pregrado) Universidad Técnica Particular de Loja …
R Beltrán, J Castillo
Recuperado el 21, 2015
52015
Evaluation of different window heights and facade porosities in naturally cross-ventilated buildings: CFD validation
SF Díaz-Calderón, JA Castillo, G Huelsz
Journal of Wind Engineering and Industrial Aerodynamics 232, 105263, 2023
42023
Natural ventilation in a room with a horizontal cylindrical heat source, a window and bottom or top vents
JA Castillo, R Tovar, G Huelsz
Building and Environment 191, 107583, 2021
42021
Visualización de plumas y medición de gradientes térmicos por medio de schlieren sintético
LP Thomas, BM Marino, R Tovar Olvera, JA Castillo, JA Rojas Menéndez
Avances en Energías Renovables y Medio Ambiente 13, 2009
42009
Enfriamiento pasivo por techos fríos en habitaciones
R Tovar, JA Castillo
Memorias de la 33, 2009
32009
Indoor air quality evaluation in naturally cross-ventilated buildings for education using age of air
SF Díaz-Calderón, JA Castillo, G Huelsz
Journal of Physics: Conference Series 2069 (1), 012182, 2021
22021
Flujos generados por una fuente de calor en un recinto con cielorraso a temperatura constante y aberturas
LP Thomas, BM Marino, R Tovar Olvera, JA Castillo
Avances en Energías Renovables y Medio Ambiente 15, 2011
22011
Natural ventilation by windcatchers: CFD simulations and experiments
JA Castillo, G Huelsz, MV Cruz
Hamburg, Germany. CWE, 2014
12014
Modelado analítico de la ventilación en una habitación con cielorraso enfriado y fuente de calor, conectada al exterior
LP Thomas, BM Marino, R Tovar, JA Castillo
Avances en Energías Renovables y Medio Ambiente-AVERMA 16, 57-64, 2012
12012
The system can't perform the operation now. Try again later.
Articles 1–20