Calculating steady-state operating conditions for doubly-fed induction generator wind turbines
JF Medina-Padrón, AE Feijóo-Lorenzo
IEEE transactions on power systems 25 (2), 922-928, 2010
89*2010
Analysis of a pumped storage system to increase the penetration level of renewable energy in isolated power systems. Gran Canaria: a case study
S Padrón, JF Medina, A Rodríguez
Energy 36 (12), 6753-6762, 2011
692011
An offshore wind atlas for the Canary Islands
AC Martín-Mederos, JF Medina-Padrón, AE Feijóo-Lorenzo
Renewable and sustainable energy Reviews 15 (1), 612-620, 2011
242011
Critical Clearing Time and Wind Power in Small Isolated Power Systems Considering Inertia Emulation
EJ Medina-Domínguez, JF Medina-Padrón
Energies 8 (11), 12669-12684, 2015
92015
Power output of a wind turbine installed in an already existing viaduct
Ó Soto-Hernández, K Volkov, AC Martín-Mederos, JF Medina-Padrón, ...
Renewable and Sustainable Energy Reviews 48, 287-299, 2015
42015
A linear approach to study the influence of asynchronous wind parks on isolated networks
C Carrillo, AE Feijóo, J Cidrás, JF Medina
Electric power systems research 77 (8), 1028-1037, 2007
32007
Energy Supply to a Small Island by Wind and Hydropower: Dynamic Analysis
N Angulo, JF Medina, F Déniz, J Cidrás, CJ Carrillo, C Bueno
Proceedings of Global Wind Power Conference and Exhibition, Paris, France, 2002
32002
ANALYSIS OF THE BEHAVIOUR OF ASYNCHRONOUS WIND TURBINES UNDER NETWORK FREQUENCY VARIATIONS
N Angulo, JF Medina, J Cidrás, C Carrillo, A Feijóo
Erupean Union Wind Energy Conf., 2003, 2003
22003
Análisis de sistemas eléctricos ante la integración de parques eólicos. Aplicación al caso de las Islas Canarias
JF Medina-Padrón
Universidad de Las Palmas de Gran Canaria, 1997
21997
Análisis de implantación de microrredes en el sistema eléctrico de Gran Canaria
JJ Prieto de la Torre, JF Medina-Padrón, EJ Medina-Domínguez, ...
EEEJ: Electrical Engineering Electronic Journal 1 (2), 2016
1*2016
Influence of wind power fluctuations on network voltage and frequency
JF Medina, J Cidrás
EWEC-CONFERENCE-, 770-773, 1999
11999
Simplified methods for the study of frequency and voltage, in the evaluation of the impact of wind farms on power systems
JF Medina, J Cidras
EWEC-CONFERENCE-, 784-787, 1997
11997
Prediction system based on domotic weather sensors for the energy production of solar power plants
D Benítez, C González-Muñoz, JF Medina
Renewable Energy and Power Quality Journal, 0
1*
Caso práctico de alta penetración de energías renovables en un sistema eléctrico
F Cabrera-Quintero, JF Medina-Padrón
Libro de Resúmenes de lasJornadas de la Universidad de Las Palmas de …, 2017
2017
Integración de aerogeneradores síncronos multipolos en sistemas eléctricos aislados considerando la máxima duración de cortocircuito
EJM Domínguez, JFM Padrón
DYNA Ingeniería e Industria 91 (2), 126, 2016
2016
Integration of Full Converter Wind Turbines into Isolated Power Systems and Maximum Short Circuit Duration
EJ Medina-Domínguez, JF Medina Padrón
DYNA 91 (2), 126, 2016
2016
EL TIEMPO CRÍTICO DE ELIMINACIÓN Y LA INCORPORACIÓN DE AEROGENERADORES SÍNCRONOS MULTIPOLOS A SISTEMAS ELÉCTRICOS PEQUEÑOS Y AISLADOS
EJM DOMINGUEZ, JFM PADRON
DYNA Energía y Sostenibilidad 4 (1), 2015
2015
Arquitecturas basadas en computadores empotrados para la gestión inteligente de la energía en un complejo hotelero
C González Muñoz, D Benítez Díaz, L Carrasco Medina, ...
2010
PG3. 31 A Contribution to the Short-Circuit Analysis of Weak Networks Containing Wind Turbines
N Angulo, JF Medina, J Cidras
EWEC-CONFERENCE-, 1106-1109, 2001
2001
Wind power integration improvement in an island by installing battery energy storage systems. Case study of Lanzarote-Fuerteventura.
L Mejías-García, JF Medina-Padrón, EJ Medina-Domínguez
El sistema no puede realizar la operación en estos momentos. Inténtalo de nuevo más tarde.