Follow
John J. van den Dobbelsteen
John J. van den Dobbelsteen
Full Professor at Delft University of Technology
Verified email at vandendobbelsteen.nl
Title
Cited by
Cited by
Year
Needle–tissue interaction forces–A survey of experimental data
DJ van Gerwen, J Dankelman, JJ van den Dobbelsteen
Medical engineering & physics 34 (6), 665-680, 2012
2792012
Three-dimensional needle shape reconstruction using an array of fiber bragg grating sensors
RJ Roesthuis, M Kemp, JJ van den Dobbelsteen, S Misra
IEEE/ASME transactions on mechatronics 19 (4), 1115-1126, 2013
2742013
Sensory integration does not lead to sensory calibration
JBJ Smeets, JJ van den Dobbelsteen, DDJ de Grave, RJ van Beers, ...
Proceedings of the National Academy of Sciences 103 (49), 18781-18786, 2006
2382006
Design choices in needle steering—A review
NJ Van De Berg, DJ Van Gerwen, J Dankelman, JJ Van Den Dobbelsteen
IEEE/ASME Transactions on Mechatronics 20 (5), 2172-2183, 2014
1492014
Force feedback and basic laparoscopic skills
MK Chmarra, J Dankelman, JJ van den Dobbelsteen, FW Jansen
Surgical endoscopy 22, 2140-2148, 2008
1172008
Forces applied to the maxillary incisors during video-assisted intubation
RA Lee, AAJ van Zundert, RLJG Maassen, RJ Willems, LP Beeke, ...
Anesthesia & Analgesia 108 (1), 187-191, 2009
1052009
Force measurement platform for training and assessment of laparoscopic skills
T Horeman, SP Rodrigues, FW Jansen, J Dankelman, ...
Surgical endoscopy 24, 3102-3108, 2010
1002010
Sterilization of disposable face masks by means of standardized dry and steam sterilization processes; an alternative in the fight against mask shortages due to COVID-19
P De Man, B van Straten, J van den Dobbelsteen, A Van Der Eijk, ...
Journal of Hospital Infection 105 (2), 356-357, 2020
992020
Assessment of laparoscopic skills based on force and motion parameters
T Horeman, J Dankelman, FW Jansen, JJ van den Dobbelsteen
IEEE Transactions on Biomedical Engineering 61 (3), 805-813, 2013
952013
Accuracy of needle position measurements using fiber Bragg gratings
K Henken, D Van Gerwen, J Dankelman, J Van Den Dobbelsteen
Minimally Invasive Therapy & Allied Technologies 21 (6), 408-414, 2012
922012
Design of an actively controlled steerable needle with tendon actuation and FBG-based shape sensing
NJ van de Berg, J Dankelman, JJ van den Dobbelsteen
Medical engineering & physics 37 (6), 617-622, 2015
912015
Error Analysis of FBG-Based Shape Sensors for Medical Needle Tracking
KR Henken, J Dankelman, JJ van den Dobbelsteen, LK Cheng, ...
Transactions on Mechatronics, 1-9, 2013
852013
Endpoints of arm movements to visual targets
JJ van den Dobbelsteen, E Brenner, JB Smeets
Experimental Brain Research 138, 279-287, 2001
742001
Force parameters for skills assessment in laparoscopy
T Horeman, SP Rodrigues, FW Jansen, J Dankelman, ...
IEEE Transactions on Haptics 5 (4), 312-322, 2011
692011
Visual force feedback improves knot-tying security
T Horeman, MD Blikkendaal, D Feng, A van Dijke, FW Jansen, ...
Journal of surgical education 71 (1), 133-141, 2014
662014
Visual force feedback in laparoscopic training
T Horeman, SP Rodrigues, JJ van den Dobbelsteen, FW Jansen, ...
Surgical endoscopy 26, 242-248, 2012
632012
Friction dynamics of trocars
JJ Van den Dobbelsteen, A Schooleman, J Dankelman
Surgical endoscopy 21, 1338-1343, 2007
582007
Needle placement errors: do we need steerable needles in interventional radiology?
TL De Jong, NJ Van De Berg, L Tas, A Moelker, J Dankelman, ...
Medical Devices: Evidence and Research, 259-265, 2018
502018
Effect of laparoscopic grasper force transmission ratio on grasp control
EP Westebring-van der Putten, JJ van den Dobbelsteen, RHM Goossens, ...
Surgical endoscopy 23, 818-824, 2009
502009
The art of electrosurgery: trainees and experts
FC Meeuwsen, ACP Guédon, EA Arkenbout, M van der Elst, J Dankelman, ...
Surgical innovation 24 (4), 373-378, 2017
482017
The system can't perform the operation now. Try again later.
Articles 1–20