spektr 3.0—A computational tool for x‐ray spectrum modeling and analysis J Punnoose, J Xu, A Sisniega, W Zbijewski, JH Siewerdsen Medical physics 43 (8Part1), 4711-4717, 2016 | 285 | 2016 |
Modelling the physics in the iterative reconstruction for transmission computed tomography J Nuyts, B De Man, JA Fessler, W Zbijewski, FJ Beekman Physics in Medicine & Biology 58 (12), R63, 2013 | 273 | 2013 |
Dedicated cone-beam CT system for extremity imaging JA Carrino, A Al Muhit, W Zbijewski, GK Thawait, JW Stayman, N Packard, ... Radiology 270 (3), 816-824, 2014 | 240 | 2014 |
Efficient Monte Carlo based scatter artifact reduction in cone-beam micro-CT W Zbijewski, FJ Beekman IEEE transactions on medical imaging 25 (7), 817-827, 2006 | 193 | 2006 |
A dedicated cone‐beam CT system for musculoskeletal extremities imaging: design, optimization, and initial performance characterization W Zbijewski, P De Jean, P Prakash, Y Ding, JW Stayman, N Packard, ... Medical physics 38 (8), 4700-4713, 2011 | 183 | 2011 |
Analysis of Fourier‐domain task‐based detectability index in tomosynthesis and cone‐beam CT in relation to human observer performance GJ Gang, J Lee, JW Stayman, DJ Tward, W Zbijewski, JL Prince, ... Medical physics 38 (4), 1754-1768, 2011 | 173 | 2011 |
Flexible adult acquired flatfoot deformity: comparison between weight-bearing and non-weight-bearing measurements using cone-beam computed tomography C de Cesar Netto, LC Schon, GK Thawait, LF Da Fonseca, ... JBJS 99 (18), e98, 2017 | 154 | 2017 |
Monte Carlo study of the effects of system geometry and antiscatter grids on cone‐beam CT scatter distributions A Sisniega, W Zbijewski, A Badal, IS Kyprianou, JW Stayman, JJ Vaquero, ... Medical physics 40 (5), 051915, 2013 | 154 | 2013 |
Mobile C‐arm cone‐beam CT for guidance of spine surgery: image quality, radiation dose, and integration with interventional guidance S Schafer, S Nithiananthan, DJ Mirota, A Uneri, JW Stayman, W Zbijewski, ... Medical physics 38 (8), 4563-4574, 2011 | 149 | 2011 |
Demons deformable registration of CT and cone‐beam CT using an iterative intensity matching approach S Nithiananthan, S Schafer, A Uneri, DJ Mirota, JW Stayman, W Zbijewski, ... Medical physics 38 (4), 1785-1798, 2011 | 117 | 2011 |
High-fidelity artifact correction for cone-beam CT imaging of the brain A Sisniega, W Zbijewski, J Xu, H Dang, JW Stayman, J Yorkston, N Aygun, ... Physics in Medicine & Biology 60 (4), 1415, 2015 | 112 | 2015 |
Task‐based detectability in CT image reconstruction by filtered backprojection and penalized likelihood estimation GJ Gang, JW Stayman, W Zbijewski, JH Siewerdsen Medical physics 41 (8Part1), 081902, 2014 | 104 | 2014 |
Assessment of image quality in soft tissue and bone visualization tasks for a dedicated extremity cone-beam CT system S Demehri, A Muhit, W Zbijewski, JW Stayman, J Yorkston, N Packard, ... European radiology 25, 1742-1751, 2015 | 100 | 2015 |
Motion compensation in extremity cone-beam CT using a penalized image sharpness criterion A Sisniega, JW Stayman, J Yorkston, JH Siewerdsen, W Zbijewski Physics in Medicine & Biology 62 (9), 3712, 2017 | 98 | 2017 |
Automatic localization of vertebral levels in x-ray fluoroscopy using 3D-2D registration: a tool to reduce wrong-site surgery Y Otake, S Schafer, JW Stayman, W Zbijewski, G Kleinszig, R Graumann, ... Physics in Medicine & Biology 57 (17), 5485, 2012 | 88 | 2012 |
Extra‐dimensional Demons: a method for incorporating missing tissue in deformable image registration S Nithiananthan, S Schafer, DJ Mirota, JW Stayman, W Zbijewski, DD Reh, ... Medical physics 39 (9), 5718-5731, 2012 | 78 | 2012 |
Extremity cone-beam CT for evaluation of medial tibiofemoral osteoarthritis: Initial experience in imaging of the weight-bearing and non-weight-bearing knee JHS Gaurav K. Thawait, Shadpour Demehri, Abdullah AlMuhit, Wojciech ... European Journal of Radiology 84 (12), 2564-2570, 2015 | 77 | 2015 |
Characterization and suppression of edge and aliasing artefacts in iterative x-ray CT reconstruction W Zbijewski, FJ Beekman Physics in Medicine & Biology 49 (1), 145, 2003 | 73 | 2003 |
Task‐based modeling and optimization of a cone‐beam CT scanner for musculoskeletal imaging P Prakash, W Zbijewski, GJ Gang, Y Ding, JW Stayman, J Yorkston, ... Medical physics 38 (10), 5612-5629, 2011 | 71 | 2011 |
Cone-beam CT measurements of distal tibio-fibular syndesmosis in asymptomatic uninjured ankles: does weight-bearing matter? D Shakoor, GM Osgood, M Brehler, WB Zbijewski, C de Cesar Netto, ... Skeletal radiology 48, 583-594, 2019 | 68 | 2019 |