Seguir
Riccardo Vismara
Riccardo Vismara
Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
Dirección de correo verificada de polimi.it
Título
Citado por
Citado por
Año
Impact of different aortic valve calcification patterns on the outcome of transcatheter aortic valve implantation: A finite element study
F Sturla, M Ronzoni, M Vitali, A Dimasi, R Vismara, G Preston-Maher, ...
Journal of biomechanics 49 (12), 2520-2530, 2016
892016
Transcatheter edge-to-edge treatment of functional tricuspid regurgitation in an ex vivo pulsatile heart model
R Vismara, G Gelpi, S Prabhu, P Romitelli, LG Troxler, A Mangini, ...
Journal of the American College of Cardiology 68 (10), 1024-1033, 2016
882016
In vitro hemodynamics and valve imaging in passive beating hearts
AM Leopaldi, R Vismara, M Lemma, L Valerio, M Cervo, A Mangini, ...
Journal of biomechanics 45 (7), 1133-1139, 2012
572012
In vitro comparison of three techniques for ventriculo-aortic junction annuloplasty
L de Kerchove, R Vismara, A Mangini, GB Fiore, J Price, P Noirhomme, ...
European journal of cardio-thoracic surgery 41 (5), 1117-1124, 2012
552012
A new pulsatile volumetric device with biomorphic valves for the in vitro study of the cardiovascular system
E Lanzarone, R Vismara, GB Fiore
Artificial organs 33 (12), 1048-1062, 2009
502009
A novel approach to the in vitro hydrodynamic study of the aortic valve: mock loop development and test
R Vismara, GB Fiore, A Mangini, M Contino, M Lemma, A Redaelli, ...
Asaio Journal 56 (4), 279-284, 2010
432010
A novel passive left heart platform for device testing and research
AM Leopaldi, R Vismara, S Van Tuijl, A Redaelli, FN van de Vosse, ...
Medical engineering & physics 37 (4), 361-366, 2015
412015
A bioreactor with compliance monitoring for heart valve grafts
R Vismara, M Soncini, G Talò, L Dainese, A Guarino, A Redaelli, GB Fiore
Annals of biomedical engineering 38, 100-108, 2010
372010
A Pulsatile Simulator for the in Vitro Analysis of the Mitral Valve with Tri-Axial Papillary Muscle Displacement
R Vismara, A Pavesi, E Votta, M Taramasso, F Maisano, GB Fiore
The International journal of artificial organs 34 (4), 383-391, 2011
332011
In vitro and in silico approaches to quantify the effects of the Mitraclip® system on mitral valve function
F Sturla, R Vismara, M Jaworek, E Votta, P Romitelli, OA Pappalardo, ...
Journal of biomechanics 50, 83-92, 2017
312017
In vitro assessment of mitral valve function in cyclically pressurized porcine hearts
R Vismara, AM Leopaldi, M Piola, C Asselta, M Lemma, C Antona, ...
Medical Engineering & Physics 38 (4), 346-353, 2016
312016
Full mimicking of coronary hemodynamics for ex-vivo stimulation of human saphenous veins
M Piola, M Ruiter, R Vismara, V Mastrullo, M Agrifoglio, M Zanobini, ...
Annals of biomedical engineering 45, 884-897, 2017
302017
The aortic interleaflet triangles annuloplasty: a multidisciplinary appraisal
A Mangini, MG Lemma, M Soncini, E Votta, M Contino, R Vismara, ...
European journal of cardio-thoracic surgery 40 (4), 851-857, 2011
282011
Comparison of the performance of a sutureless bioprosthesis with two pericardial stented valves on small annuli: an in vitro study
G Tasca, R Vismara, A Mangini, C Romagnoni, M Contino, A Redaelli, ...
The Annals of Thoracic Surgery 103 (1), 139-144, 2017
222017
Experimental setup to evaluate the performance of percutaneous pulmonary valved stent in different outflow tract morphologies
R Vismara, K Laganà, F Migliavacca, S Schievano, L Coats, A Taylor, ...
Artificial Organs 33 (1), 46-53, 2009
212009
Fluid-dynamic results of in vitro comparison of four pericardial bioprostheses implanted in small porcine aortic roots
G Tasca, R Vismara, GB Fiore, A Mangini, C Romagnoni, S Pelenghi, ...
European Journal of Cardio-Thoracic Surgery 47 (2), e62-e67, 2015
192015
Does the type of suture technique affect the fluid-dynamic performance of bioprostheses implanted in small aortic roots? Results from an in vitro study
G Tasca, R Vismara, GB Fiore, C Romagnoni, A Redaelli, C Antona, ...
The Journal of Thoracic and Cardiovascular Surgery 149 (3), 912-918, 2015
152015
In vitro study of the aortic interleaflet triangle reshaping
R Vismara, AM Leopaldi, A Mangini, C Romagnoni, M Contino, C Antona, ...
Journal of Biomechanics 47 (2), 329-333, 2014
132014
Opening/closing pattern of Trifecta and Freestyle valves versus native aortic valve: Are stentless valves more physiologic than a stented valve?
G Tasca, R Vismara, F Trinca, B Riva, A Gamba, E Lobiati
Journal of Cardiac Surgery 32 (11), 680-685, 2017
122017
Functional tricuspid regurgitation model in a beating heart platform
M Jaworek, M Piola, F Lucherini, G Gelpi, M Castagna, G Lentini, ...
ASAIO Journal 63 (4), 438-444, 2017
122017
El sistema no puede realizar la operación en estos momentos. Inténtalo de nuevo más tarde.
Artículos 1–20