Seguir
Bo Håkansson
Bo Håkansson
Dirección de correo verificada de chalmers.se
Título
Citado por
Citado por
Año
An osseointegrated human-machine gateway for long-term sensory feedback and motor control of artificial limbs
M Ortiz-Catalan, B Håkansson, R Brånemark
Science translational medicine 6 (257), 257re6-257re6, 2014
4852014
The bone-anchored hearing aid: Design principles, indications, and long-term clinical results
A Tjellstrom, B Hakansson
Otolaryngologic clinics of north America 28 (1), 53-72, 1995
3111995
Ten years of experience with the Swedish bone-anchored hearing system
G Lidén, M Jacobsson, BO Håkansson, A Tjellström, P Carlsson, ...
Annals of Otology, Rhinology & Laryngology 99 (10_suppl), 1-16, 1990
2701990
New developments in bone-conduction hearing implants: a review
S Reinfeldt, B Håkansson, H Taghavi, M Eeg-Olofsson
Medical Devices: Evidence and Research, 79-93, 2015
2672015
BioPatRec: A modular research platform for the control of artificial limbs based on pattern recognition algorithms
M Ortiz-Catalan, R Brånemark, B Håkansson
Source code for biology and medicine 8, 1-18, 2013
2452013
Bone-anchored hearing aids: current status in adults and children
A Tjellström, BO Håkansson, G Granström
Otolaryngologic Clinics of North America 34 (2), 337-364, 2001
2422001
Treatment of phantom limb pain (PLP) based on augmented reality and gaming controlled by myoelectric pattern recognition: a case study of a chronic PLP patient
M Ortiz-Catalan, N Sander, MB Kristoffersen, B Håkansson, R Brånemark
Frontiers in neuroscience 8, 71345, 2014
2402014
The bone-anchored hearing aid: principal design and a psychoacoustical evaluation
B Håkansson, A Tjellström, U Rosenhall, P Carlsson
Acta oto-laryngologica 100 (3-4), 229-239, 1985
2331985
Hearing thresholds with direct bone conduction versus conventional bone conduction
B Håkansson, A Tjellström, U Rosenhall
Scandinavian audiology 13 (1), 3-13, 1984
2181984
Vibration characteristics of bone conducted sound in vitro
S Stenfelt, B Håkansson, A Tjellström
The Journal of the Acoustical Society of America 107 (1), 422-431, 2000
1952000
On the viability of implantable electrodes for the natural control of artificial limbs: review and discussion
M Ortiz-Catalan, R Brånemark, B Håkansson, J Delbeke
Biomedical engineering online 11, 1-24, 2012
1742012
Real-time and simultaneous control of artificial limbs based on pattern recognition algorithms
M Ortiz-Catalan, B Håkansson, R Brånemark
IEEE Transactions on Neural Systems and Rehabilitation Engineering 22 (4 …, 2014
1672014
Resonance frequencies of the human skull invivo
B Håkansson, A Brandt, P Carlsson, A Tjellström
The Journal of the Acoustical Society of America 95 (3), 1474-1481, 1994
1621994
Analysis of the mechanical impedance of bone-anchored hearing aids
A Tjellström, B Håkansson, J Lindström, PI Brånemark, O Hallen, ...
Acta oto-laryngologica 89 (1-2), 85-92, 1980
1371980
Bilateral bone‐anchored hearing aids (BAHAs): an audiometric evaluation
C Priwin, S Stenfelt, G Granström, A Tjellström, B Håkansson
The Laryngoscope 114 (1), 77-84, 2004
1302004
Biomechanical characterisation of bone-anchored implant systems for amputation limb prostheses: a systematic review
A Thesleff, R Brånemark, B Håkansson, M Ortiz-Catalan
Annals of biomedical engineering 46, 377-391, 2018
1272018
A novel bone conduction implant (BCI): engineering aspects and pre-clinical studies
B Håkansson, S Reinfeldt, M Eeg-Olofsson, P Östli, H Taghavi, J Adler, ...
International journal of audiology 49 (3), 203-215, 2010
1102010
The mechanical point impedance of the human head, with and without skin penetration
B Håkansson, P Carlsson, A Tjellström
The Journal of the Acoustical Society of America 80 (4), 1065-1075, 1986
1101986
Air versus bone conduction: an equal loudness investigation
S Stenfelt, B Håkansson
Hearing research 167 (1-2), 1-12, 2002
1072002
Embedded system for prosthetic control using implanted neuromuscular interfaces accessed via an osseointegrated implant
E Mastinu, P Doguet, Y Botquin, B Håkansson, M Ortiz-Catalan
IEEE transactions on biomedical circuits and systems 11 (4), 867-877, 2017
1062017
El sistema no puede realizar la operación en estos momentos. Inténtalo de nuevo más tarde.
Artículos 1–20