Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality J Geleijns, M Salvado Artells, WJH Veldkamp, M Lopez Tortosa, ... European radiology 16, 2334-2340, 2006 | 172 | 2006 |
Computed tomography dose assessment for a 160 mm wide, 320 detector row, cone beam CT scanner J Geleijns, MS Artells, PW De Bruin, R Mather, Y Muramatsu, ... Physics in Medicine & Biology 54 (10), 3141, 2009 | 119 | 2009 |
Dosimetry of a cone beam CT device for oral and maxillofacial radiology using Monte Carlo techniques and ICRP adult reference computational phantoms JJ Morant, M Salvadó, I Hernández‐Girón, R Casanovas, R Ortega, ... Dentomaxillofacial Radiology, 92555893, 2012 | 105 | 2012 |
Energy and resolution calibration of NaI (Tl) and LaBr< sub> 3</sub>(Ce) scintillators and validation of an EGS5 Monte Carlo user code for efficiency calculations R Casanovas, JJ Morant, M Salvadó Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2012 | 90 | 2012 |
Temperature peak-shift correction methods for NaI (Tl) and LaBr< sub> 3</sub>(Ce) gamma-ray spectrum stabilisation R Casanovas, JJ Morant, M Salvadó Radiation Measurements 47 (8), 588-595, 2012 | 75 | 2012 |
Implementation of gamma-ray spectrometry in two real-time water monitors using NaI (Tl) scintillation detectors R Casanovas, JJ Morant, M Salvadó Applied Radiation and Isotopes 80, 49-55, 2013 | 54 | 2013 |
Calculation of the ambient dose equivalent H*(10) from gamma-ray spectra obtained with scintillation detectors R Casanovas, E Prieto, M Salvadó Applied Radiation and Isotopes 118, 154-159, 2016 | 42 | 2016 |
Radiation exposure to patients in a multicenter coronary angiography trial (CORE 64) J Geleijns, RMS Joemai, M Dewey, A de Roos, M Zankl, AC Cantera, ... American Journal of Roentgenology 196 (5), 1126-1132, 2011 | 42 | 2011 |
Monte Carlo calculation of radiation dose in CT examinations using phantom and patient tomographic models M Salvado, M Lopez, JJ Morant, A Calzado Radiation protection dosimetry 114 (1-3), 364-368, 2005 | 40 | 2005 |
Development and calibration of a real-time airborne radioactivity monitor using direct gamma-ray spectrometry with two scintillation detectors R Casanovas, JJ Morant, M Salvadó Applied Radiation and Isotopes 89, 102-108, 2014 | 34 | 2014 |
Validation of a Monte Carlo simulation for dose assessment in dental cone beam CT examinations JJ Morant, M Salvadó, R Casanovas, I Hernández-Girón, E Velasco, ... Physica Medica 28 (3), 200-209, 2012 | 30 | 2012 |
Performance of data acceptance criteria over 50 months from an automatic real-time environmental radiation surveillance network R Casanovas, JJ Morant, M López, I Hernández-Girón, E Batalla, ... Journal of environmental radioactivity 102 (8), 742-748, 2011 | 26 | 2011 |
Falcultat de Med. i Cienc. de la Salut, Univ. Rovira i Virgili, Reus, Spain R Casanovas, JJ Morant, M Salvado Real Time Conference (RT), 2012 18th IEEE-NPSS, 1-4, 2012 | 19* | 2012 |
Development and calibration of a real-time airborne radioactivity monitor using gamma-ray spectrometry on a particulate filter R Casanovas, JJ Morant, M Salvado Real Time Conference (RT), 2012 18th IEEE-NPSS, 1-4, 2012 | 19 | 2012 |
SimDoseCT: dose reporting software based on Monte Carlo simulation for a 320 detector-row cone-beam CT scanner and ICRP computational adult phantoms M Cros, RMS Joemai, J Geleijns, D Molina, M Salvadó Physics in Medicine & Biology 62 (15), 6304, 2017 | 16 | 2017 |
Perfusion CT of the brain and liver and of lung tumors: use of Monte Carlo simulation for patient dose estimation for examinations with a cone-beam 320-MDCT scanner M Cros, J Geleijns, RMS Joemai, M Salvadó American Journal of Roentgenology 206 (1), 129-135, 2016 | 12 | 2016 |
Estado actual y tendencia en el desarrollo tecnológico para la reducción de dosis en los equipos de tomografía computarizada AC Cantera, I Hernández-Girón, MS Artells, RR González Radiologia 55, 9-16, 2013 | 10 | 2013 |
Monte Carlo simulation of the dose distribution of ICRP adult reference computational phantoms for acquisitions with a 320 detector-row cone-beam CT scanner M Salvadó, M Cros, RMS Joemai, A Calzado, J Geleijns Physica Medica 31 (5), 452-462, 2015 | 9 | 2015 |
Calibration and performance of a real-time gamma-ray spectrometry water monitor using a LaBr3 (Ce) detector E Prieto, R Casanovas, M Salvadó Radiation Physics and Chemistry 144, 444-450, 2018 | 8 | 2018 |
Set up of a gamma spectrometry mobile unit equipped with LaBr3 (Ce) detectors for radioactivity monitoring E Prieto, E Jabaloyas, R Casanovas, C Rovira, M Salvadó Radiation Physics and Chemistry 168, 108600, 2020 | 7 | 2020 |