Performance analysis of earth–pipe–air heat exchanger for summer cooling V Bansal, R Misra, GD Agrawal, J Mathur Energy and buildings 42 (5), 645-648, 2010 | 386 | 2010 |
Performance analysis of earth–pipe–air heat exchanger for winter heating V Bansal, R Misra, GD Agrawal, J Mathur Energy and Buildings 41 (11), 1151-1154, 2009 | 276 | 2009 |
Targeting for cogeneration potential through total site integration S Bandyopadhyay, J Varghese, V Bansal Applied Thermal Engineering 30 (1), 6-14, 2010 | 172 | 2010 |
CFD analysis based parametric study of derating factor for Earth Air Tunnel Heat Exchanger R Misra, V Bansal, GD Agrawal, J Mathur, TK Aseri Applied Energy 103, 266-277, 2013 | 153 | 2013 |
Performance analysis of integrated earth–air-tunnel-evaporative cooling system in hot and dry climate V Bansal, R Mishra, GD Agarwal, J Mathur Energy and Buildings 47, 525-532, 2012 | 138 | 2012 |
Transient effect of soil thermal conductivity and duration of operation on performance of Earth Air Tunnel Heat Exchanger V Bansal, R Misra, GD Agarwal, J Mathur Applied Energy 103, 1-11, 2013 | 135 | 2013 |
‘Derating Factor’new concept for evaluating thermal performance of earth air tunnel heat exchanger: A transient CFD analysis V Bansal, R Misra, GD Agarwal, J Mathur Applied Energy 102, 418-426, 2013 | 114 | 2013 |
Thermal performance investigation of hybrid earth air tunnel heat exchanger R Misra, V Bansal, GD Agarwal, J Mathur, T Aseri Energy and Buildings 49, 531-535, 2012 | 89 | 2012 |
Thermal performance investigation of earth air tunnel heat exchanger coupled with a solar air heating duct for northwestern India S Jakhar, R Misra, V Bansal, MS Soni Energy and Buildings 87, 360-369, 2015 | 88 | 2015 |
Transient analysis based determination of derating factor for earth air tunnel heat exchanger in summer R Misra, V Bansal, GD Agrawal, J Mathur, T Aseri Energy and buildings 58, 103-110, 2013 | 67 | 2013 |
Performance evaluation and economic analysis of integrated earth–air–tunnel heat exchanger–evaporative cooling system V Bansal, R Misra, GD Agrawal, J Mathur Energy and Buildings 55, 102-108, 2012 | 52 | 2012 |
Transient analysis based determination of derating factor for Earth Air Tunnel Heat Exchanger in winter R Misra, V Bansal, GD Agrawal, J Mathur, T Aseri Energy and Buildings 58, 76-85, 2013 | 51 | 2013 |
Optimization of operating parameters of earth air tunnel heat exchanger for space cooling: Taguchi method approach KK Agrawal, M Bhardwaj, R Misra, G Das Agrawal, V Bansal Geothermal Energy 6, 1-17, 2018 | 41 | 2018 |
Performance enhancement of earth air tunnel heat exchanger using evaporative cooling V Bansal, J Mathur International Journal of Low-Carbon Technologies 4 (3), 150-158, 2009 | 38 | 2009 |
Evaluating thermal performance and energy conservation potential of hybrid earth air tunnel heat exchanger in hot and dry climate—in situ measurement R Misra, V Bansal, G Das Agarwal, J Mathur, T Aseri Journal of Thermal Science and Engineering Applications 5 (3), 031006, 2013 | 22 | 2013 |
CFD analysis of thermal influence zone of earth air tunnel heat exchanger under transient conditions R Misra, TK Aseri, V Bansal Proceedings of BS2015 14th Conference of International Building Performance …, 2015 | 15 | 2015 |
Development of passive energy source as earth air pipe heat exchangers (eaphe) system-a review M Verma, V Bansal, K Rana Journal of Thermal Engineering 6 (5), 651-676, 2020 | 11 | 2020 |
Review on finite element analysis for estimation of residual stresses in welded structures BP Mahur, Y Bhardwaj, V Bansal Materials Today: Proceedings 4 (9), 10230-10234, 2017 | 5 | 2017 |
A comprehensive review on EATHE RS Jhala, V Bansal VII, 530-543, 2016 | 3 | 2016 |
IInvestigation of Thermal Performance of EATHE System under Intermittent Operation: A CFD Approach AA Rohit Misra, Vikas Bansal International Journal of Engineering Technology, Management and Applied …, 2016 | 3 | 2016 |