Seguir
Françoise Lliso
Françoise Lliso
Especialista en Radiofísica Hospitalaria. Radioterapia.
Dirección de correo verificada de gva.es
Título
Citado por
Citado por
Año
Monte Carlo calculation of dose rate distributions around wires
F Ballester, C Hernández, J Pérez‐Calatayud, F Lliso
Medical physics 24 (8), 1221-1228, 1997
911997
Dosimetric characteristics of a new unit for electronic skin brachytherapy
T Garcia-Martinez, JP Chan, J Perez-Calatayud, F Ballester
Journal of Contemporary Brachytherapy 6 (1), 45-53, 2014
622014
Monte Carlo calculations of dose rate distributions around the Amersham CDCS‐M‐type source
E Casal, F Ballester, JL Lluch, J Pérez‐Calatayud, F Lliso
Medical Physics 27 (1), 132-140, 2000
402000
Fitted dosimetric parameters of high dose‐rate sources according to the AAPM TG43 formalism
F Lliso, J Pérez‐Calatayud, V Carmona, F Ballester, JL Lluch, MA Serrano, ...
Medical physics 28 (4), 654-660, 2001
312001
Monte Carlo dosimetry of the Buchler high dose rate 192Ir source
F Ballester, J Pérez-Calatayud, V Puchades, JL Lluch, ...
Physics in Medicine & Biology 46 (3), N79, 2001
312001
Commissioning and initial experience with a commercial software for in vivo volumetric dosimetry
J Gimeno, MC Pujades, T García, V Carmona, F Lliso, R Palomo, ...
Physica Medica 30 (8), 954-959, 2014
302014
A Monte Carlo investigation of the dosimetric characteristics of the CSM11 source from CIS
F Ballester, JL Lluch, Y Limami, MA Serrano, E Casal, J Pérez‐Calatayud, ...
Medical Physics 27 (9), 2182-2189, 2000
272000
Organ contouring for prostate cancer: interobserver and internal organ motion variability
X Gual-Arnau, MV Ibanez-Gual, F Lliso, S Roldan
Computerized Medical Imaging and Graphics 29 (8), 639-647, 2005
252005
Physics Contributions Dosimetric evaluation of internal shielding in a High Dose Rate skin applicator
F Lliso, D Granero, J Perez-Calatayud, V Carmona, MC Pujades, ...
Journal of Contemporary Brachytherapy 3 (1), 32-38, 2011
202011
Impact of the Tiloop Bra mesh in CT images and dose delivery in breast radiotherapy
C Camacho, J Perez‐Calatayud, F Lliso, V Carmona, A Tormo, F Ballester, ...
Journal of applied clinical medical physics 13 (2), 13-19, 2012
182012
Failure mode and effects analysis of skin electronic brachytherapy using Esteya® unit
B Ibanez-Rosello, JA Bautista-Ballesteros, J Bonaque, F Celada, F Lliso, ...
Journal of Contemporary Brachytherapy 8 (6), 518-524, 2016
172016
Physics Contributions A program for the independent verification of brachytherapy planning system calculations
V Carmona, J Perez-Calatayud, F Lliso, J Richart, F Ballester, ...
Journal of Contemporary Brachytherapy 2 (3), 129-133, 2010
162010
Monte Carlo calculation of dose rate distributions around 0.5 and 0.6 mm in diameter wires
J Pérez‐Calatayud, F Lliso, V Carmona, F Ballester, C Hernández
Medical Physics 26 (3), 395-401, 1999
151999
100% peer review in radiation oncology: is it feasible?
E Martin-Garcia, F Celada-Álvarez, MJ Pérez-Calatayud, ...
Clinical and Translational Oncology 22 (12), 2341-2349, 2020
122020
The use of nomograms in LDR-HDR prostate brachytherapy
MC Pujades, C Camacho, J Perez-Calatayud, J Richart, J Gimeno, F Lliso, ...
Journal of Contemporary Brachytherapy 3 (3), 121-124, 2011
92011
A Monte Carlo study of intersource effects in dome-type applicators loaded with LDR Cs-137 sources
J Pérez-Calatayud, D Granero, F Ballester, F Lliso
Radiotherapy and oncology 77 (2), 216-219, 2005
92005
A Monte Carlo study of dose rate distribution around the specially asymmetric CSM3-a 137Cs source
J Pérez-Calatayud, F Lliso, F Ballester, MA Serrano, JL Lluch, Y Limami, ...
Physics in Medicine & Biology 46 (7), N169, 2001
82001
Fetal dose measurements and shielding efficiency assessment in a custom setup of 192Ir brachytherapy for a pregnant woman with breast cancer
C Candela-Juan, J Gimeno-Olmos, MC Pujades, MJ Rivard, V Carmona, ...
Physica Medica 31 (3), 286-292, 2015
72015
Induced attenuation in Ce3+ and Nd3+ doped fibers irradiated with electron beams under low dose regime
JL Cruz, F Lliso-Valverde, MV Andrés, J Pérez-Calatayud
Optics communications 252 (4-6), 286-291, 2005
72005
Virtual simulation in radiation therapy planning. Report of five-year experience.
I Petschen, J Pérez-Calatayud, A Tormo, F Lliso, M Badal, V Carmona, ...
Clinical & Translational Oncology 2 (4), 2000
72000
El sistema no puede realizar la operación en estos momentos. Inténtalo de nuevo más tarde.
Artículos 1–20