Seguir
Mazen Al-Hajjar
Mazen Al-Hajjar
Dirección de correo verificada de leeds.ac.uk
Título
Citado por
Citado por
Año
Effect of cup inclination angle during microseparation and rim loading on the wear of BIOLOX® delta ceramic‐on‐ceramic total hip replacement
M Al‐Hajjar, IJ Leslie, J Tipper, S Williams, J Fisher, LM Jennings
Journal of Biomedical Materials Research Part B: Applied Biomaterials 95 (2 …, 2010
1042010
Wear of 36-mm BIOLOX® delta ceramic-on-ceramic bearing in total hip replacements under edge loading conditions
M Al-Hajjar, J Fisher, JL Tipper, S Williams, LM Jennings
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2013
932013
Wear of novel ceramic‐on‐ceramic bearings under adverse and clinically relevant hip simulator conditions
M Al‐Hajjar, LM Jennings, S Begand, T Oberbach, D Delfosse, J Fisher
Journal of Biomedical Materials Research Part B: Applied Biomaterials 101 (8 …, 2013
682013
Effect of femoral head size on the wear of metal on metal bearings in total hip replacements under adverse edge‐loading conditions
M Al‐Hajjar, J Fisher, S Williams, JL Tipper, LM Jennings
Journal of Biomedical Materials Research Part B: Applied Biomaterials 101 (2 …, 2013
572013
Comparison of ceramic‐on‐metal and metal‐on‐metal hip prostheses under adverse conditions
S Williams, M Al‐Hajjar, GH Isaac, J Fisher
Journal of Biomedical Materials Research Part B: Applied Biomaterials 101 (5 …, 2013
352013
Influence of hip joint simulator design and mechanics on the wear and creep of metal-on-polyethylene bearings
M Ali, M Al-Hajjar, S Partridge, S Williams, J Fisher, LM Jennings
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2016
322016
(iv) Enhancing the safety and reliability of joint replacement implants
LM Jennings, M Al-Hajjar, CL Brockett, S Williams, JL Tipper, E Ingham, ...
Orthopaedics and trauma 26 (4), 246-252, 2012
282012
An in vitro simulation model to assess the severity of edge loading and wear, due to variations in component positioning in hip joint replacements
O O'Dwyer Lancaster‐Jones, S Williams, LM Jennings, J Thompson, ...
Journal of Biomedical Materials Research Part B: Applied Biomaterials 106 (5 …, 2018
262018
Wear of composite ceramics in mixed‐material combinations in total hip replacement under adverse edge loading conditions
M Al‐Hajjar, S Carbone, LM Jennings, S Begand, T Oberbach, D Delfosse, ...
Journal of Biomedical Materials Research Part B: Applied Biomaterials 105 (6 …, 2017
262017
Experimental validation of finite element modelling of a modular metal-on-polyethylene total hip replacement
X Hua, L Wang, M Al-Hajjar, Z Jin, RK Wilcox, J Fisher
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2014
252014
Evaluation of a new methodology to simulate damage and wear of polyethylene hip replacements subjected to edge loading in hip simulator testing
S Partridge, JL Tipper, M Al‐Hajjar, GH Isaac, J Fisher, S Williams
Journal of Biomedical Materials Research Part B: Applied Biomaterials 106 (4 …, 2018
192018
In vitro measurement of wear in joint replacements: a stratified approach for enhanced reliability “SAFER” pre-clinical simulation testing
J Fisher, M Al-Hajjar, S Williams, LM Jennings, E Ingham
Seminars in arthroplasty 23 (4), 286-288, 2012
122012
Combined wear and ageing of ceramic-on-ceramic bearings in total hip replacement under edge loading conditions
M Al-Hajjar, L Gremillard, S Begand, T Oberbach, K Hans, D Delfosse, ...
Journal of the mechanical behavior of biomedical materials 98, 40-47, 2019
112019
An investigation into the hydrodynamic analysis of vessels with a zero or forward speed
SX Du, DA Hudson, WG Price, P Temarel
Proceedings of the Institution of Mechanical Engineers, Part M: Journal of …, 2012
112012
(v) Simulation and measurement of wear in metal-on-metal bearings in vitro-understanding the reasons for increased wear
J Fisher, M Al Hajjar, S Williams, J Tipper, E Ingham, L Jennings
Orthopaedics and Trauma 26 (4), 253-258, 2012
102012
Dynamic virtual simulation of the occurrence and severity of edge loading in hip replacements associated with variation in the rotational and translational surgical position
J Leng, M Al-Hajjar, R Wilcox, A Jones, D Barton, J Fisher
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2017
82017
Impingement in total hip arthroplasty: A geometric model
GM Pryce, B Sabu, M Al-Hajjar, RK Wilcox, J Thompson, GH Isaac, ...
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2022
72022
Wear of hard-on-hard hip prostheses: influence of head size, surgical position, material and function
M Al-Hajjar
University of Leeds, 2012
72012
Computationally efficient modelling of hip replacement separation due to small mismatches in component centres of rotation
L Etchels, L Wang, M Al-Hajjar, S Williams, J Thompson, G Isaac, ...
Journal of Biomechanics 95, 109296, 2019
52019
Wear and deformation of metal-on-polyethylene hip replacements under edge loading conditions due to variations in surgical positioning
M Ali, M Al-Hajjar, LM Jennings, J Fisher
Orthopaedic Proceedings 99 (SUPP_3), 12-12, 2017
52017
El sistema no puede realizar la operación en estos momentos. Inténtalo de nuevo más tarde.
Artículos 1–20