Phase I-II trial of concurrent capecitabine and oxaliplatin with preoperative intensity-modulated radiotherapy in patients with locally advanced rectal cancer JJ Aristu, L Arbea, J Rodriguez, JL Hernández-Lizoain, JJ Sola, ... International Journal of Radiation Oncology* Biology* Physics 71 (3), 748-755, 2008 | 44 | 2008 |
Quality assurance in IMRT: importance of the transmission through the jaws for an accurate calculation of absolute doses and relative distributions JD Azcona, RAC Siochi, I Azinovic Medical Physics 29 (3), 269-274, 2002 | 36 | 2002 |
Assessing the dosimetric impact of real-time prostate motion during volumetric modulated arc therapy JD Azcona, L Xing, X Chen, K Bush, R Li International Journal of Radiation Oncology* Biology* Physics 88 (5), 1167-1174, 2014 | 30 | 2014 |
A novel concept to include uncertainties in the evaluation of stereotactic body radiation therapy after 4D dose accumulation using deformable image registration JD Azcona, C Huesa‐Berral, M Moreno‐Jiménez, B Barbés, JJ Aristu, ... Medical Physics 46 (10), 4346-4355, 2019 | 12 | 2019 |
A system for intensity modulated dose plan verification based on an experimental pencil beam kernel obtained by deconvolution JD Azcona, J Burguete Medical physics 35 (1), 248-259, 2008 | 12 | 2008 |
Experimental pencil beam kernels derivation for 3D dose calculation in flattening filter free modulated fields JD Azcona, B Barbés, L Wang, J Burguete Physics in Medicine & Biology 61 (1), 50, 2015 | 10 | 2015 |
Development and clinical evaluation of a simple optical method to detect and measure patient external motion B Barbés, JD Azcona, E Prieto, JM de Foronda, M García, J Burguete Journal of Applied Clinical Medical Physics 16 (5), 306-321, 2015 | 10 | 2015 |
Commissioning of small field size radiosurgery cones in a 6-MV flattening filter-free beam JD Azcona, B Barbés, V Morán, J Burguete Medical Dosimetry 42 (4), 282-288, 2017 | 9 | 2017 |
Application of spherical diodes for megavoltage photon beams dosimetry B Barbés, JD Azcona, J Burguete, JM Martí‐Climent Medical physics 41 (1), 012102, 2014 | 9 | 2014 |
Radioterapia estereotáctica JJ Aristu, R Ciérvide, J Guridi, M Moreno, L Arbea, JD Azcona, LI Ramos, ... Anales del Sistema Sanitario de Navarra 32, 61-71, 2009 | 9 | 2009 |
Commissioning of a synchrotron-based proton beam therapy system for use with a Monte Carlo treatment planning system JD Azcona, B Aguilar, Á Perales, R Polo, D Zucca, L Irazola, A Viñals, ... Radiation Physics and Chemistry 204, 110708, 2023 | 7 | 2023 |
A tool for precise calculation of organ doses in voxelised geometries using GAMOS/Geant4 with a graphical user interface PA Dubois, NTP Thao, NT Trung, JD Azcona, PB Aguilar-Redondo Polish Journal of Medical Physics and Engineering 27 (1), 31-40, 2021 | 7 | 2021 |
A method using 4D dose accumulation to quantify the interplay effect in lung stereotactic body radiation therapy C Huesa-Berral, J Burguete, M Moreno-Jiménez, JD Azcona Physics in Medicine & Biology 66 (3), 035025, 2021 | 7 | 2021 |
A proposal for a Geant4 physics list for radiotherapy optimized in physics performance and CPU time P Arce, JI Lagares, JD Azcona, PB Aguilar-Redondo Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2020 | 6 | 2020 |
Stereotactic radiation therapy JJ Aristu, R Ciérvide, J Guridi, M Moreno, L Arbea, JD Azcona, LI Ramos, ... Anales del Sistema Sanitario de Navarra 32, 61-71, 2009 | 6 | 2009 |
Intensity modulated dose calculation with an improved experimental pencil‐beam kernel JD Azcona, J Burguete Medical physics 37 (9), 4634-4642, 2010 | 5 | 2010 |
Desarrollo de un sistema de verificación de tratamientos en radioterapia con modulación de intensidad JD Azcona, J Burguete Servicio de Publicaciones de la Universidad de Navarra, 2007 | 5 | 2007 |
Detailed dosimetric evaluation of inter-fraction and respiratory motion in lung stereotactic body radiation therapy based on daily 4D cone beam CT images C Huesa-Berral, C Juan-Cruz, S van Kranen, M Rossi, J Belderbos, ... Physics in Medicine & Biology 68 (1), 015005, 2022 | 4 | 2022 |
MO‐D‐108‐01: Cloud‐Based Monte Carlo Patient‐Specific Quality Assurance (QA) Method for Volumetric‐Modulated Arc Therapy (VMAT): Clinical and Educational Impacts X Chen, L Xing, E Mok, G Luxton, K Bush Medical Physics 40 (6Part23), 396-396, 2013 | 4 | 2013 |
Rectal Cancer. Case Study J Aristu, JD Azcona, M Moreno, R Martinez-Monge INTENSITY MODULATED RADIATION THERAPY. A clinical perspective, 2005 | 4 | 2005 |