Suppression of eye-blink associated artifact using single channel EEG data by combining cross-correlation with empirical mode decomposition R Patel, MPR Janawadkar, S Sengottuvel, K Gireesan, TS Radhakrishnan IEEE Sensors Journal 16 (18), 6947-6954, 2016 | 56 | 2016 |
Ocular artifact suppression from EEG using ensemble empirical mode decomposition with principal component analysis R Patel, S Sengottuvel, MP Janawadkar, K Gireesan, TS Radhakrishnan, ... Computers & Electrical Engineering 54, 78-86, 2016 | 52 | 2016 |
Common methodology for cardiac and ocular artifact suppression from EEG recordings by combining ensemble empirical mode decomposition with regression approach R Patel, K Gireesan, S Sengottuvel, MP Janawadkar, TS Radhakrishnan Journal of Medical and Biological Engineering 37, 201-208, 2017 | 29 | 2017 |
Denoising of multichannel MCG data by the combination of EEMD and ICA and its effect on the pseudo current density maps N Mariyappa, S Sengottuvel, R Patel, C Parasakthi, K Gireesan, ... Biomedical Signal Processing and Control 18, 204-213, 2015 | 28 | 2015 |
SQUID-based measurement of biomagnetic fields MP Janawadkar, TS Radhakrishnan, K Gireesan, C Parasakthi, ... Current Science, 36-45, 2010 | 21 | 2010 |
Effective extraction of visual event-related pattern by combining template matching with ensemble empirical mode decomposition R Patel, MPR Janawadkar, S Sengottuvel, K Gireesan, TS Radhakrishnan IEEE Sensors Journal 17 (7), 2146-2153, 2017 | 20 | 2017 |
Dipole location using SQUID based measurements: Application to magnetocardiography N Mariyappa, C Parasakthi, S Sengottuvel, K Gireesan, R Patel, ... Physica C: Superconductivity 477, 15-19, 2012 | 19 | 2012 |
A feasibility study to measure magnetocardiography (MCG) in unshielded environment using first order gradiometer P parimita Swain, S Sengottuvel, R Patel, A Mani, K Gireesan Biomedical Signal Processing and Control 55, 101664, 2020 | 16 | 2020 |
A combined methodology to eliminate artifacts in multichannel electrogastrogram based on independent component analysis and ensemble empirical mode decomposition S Sengottuvel, PF Khan, N Mariyappa, R Patel, S Saipriya, K Gireesan SLAS Technology: Translating Life Sciences Innovation 23 (3), 269-280, 2018 | 14 | 2018 |
Decoding non-linearity for effective extraction of the eye-blink artifact pattern from EEG recordings R Patel, K Gireesan, S Sengottuvel Pattern Recognition Letters 139, 42-49, 2020 | 12 | 2020 |
Noninvasive determination of HV interval using magnetocardiography S Senthilnathan, RJ Selvaraj, R Patel, S Satheesh, G Katholil, ... Pacing and Clinical Electrophysiology 40 (5), 568-577, 2017 | 11 | 2017 |
Establishment of 37 channel SQUID system for magnetocardiography C Parasakthi, R Patel, S Sengottuvel, N Mariyappa, K Gireesan, ... AIP Conference Proceedings 1447 (1), 871-872, 2012 | 11 | 2012 |
Optimal classification of N-back task EEG data by performing effective feature reduction R Patel, K Gireesan, R Baskaran, NVC Shekar Sādhanā 47 (4), 281, 2022 | 9 | 2022 |
An investigation on the influence of yogic methods on heart rate variability S Senthilnathan, R Patel, M Narayanan, G Katholil, MPR Janawadkar, ... Annals of Noninvasive Electrocardiology 24 (1), e12584, 2019 | 9 | 2019 |
Suppression of baseline wander artifact in Magnetocardiogram using breathing sensor R Patel, K Gireesan, S Sengottuvel, MP Janawadkar, TS Radhakrishnan Journal of Medical and Biological Engineering 37, 554-560, 2017 | 9 | 2017 |
Design and implementation of a discrete-time proportional integral (PI) controller for the temperature control of a heating pad PF Khan, S Sengottuvel, R Patel, K Gireesan, R Baskaran, A Mani SLAS TECHNOLOGY: Translating Life Sciences Innovation 23 (6), 614-623, 2018 | 7 | 2018 |
Extraction of breathing pattern using temperature sensor based on Arduino board R Patel, S Sengottuvel, K Gireesan, MP Janawadkar, TS Radhakrishnan AIP Conference Proceedings 1665 (1), 2015 | 7 | 2015 |
Magnetocardiography for identification of coronary ischemia in patients with chest pain and normal resting 12‐lead electrocardiogram R Ramesh, S Senthilnathan, S Satheesh, PP Swain, R Patel, ... Annals of Noninvasive Electrocardiology 25 (3), e12715, 2020 | 5 | 2020 |
Enhancing the reliability in the noninvasive measurement of the his bundle magnetic field using a novel signal averaging methodology S Senthilnathan, P Chandrasekaran, M Narayanan, R Patel, G Katholil, ... Annals of Noninvasive Electrocardiology 17 (3), 186-194, 2012 | 5 | 2012 |