Blaise Yvert
Blaise Yvert
Dirección de correo verificada de inserm.fr - Página principal
Título
Citado por
Citado por
Año
Multiple supratemporal sources of magnetic and electric auditory evoked middle latency components in humans
B Yvert, A Crouzeix, O Bertrand, A Seither-Preisler, C Pantev
Cerebral Cortex 11 (5), 411-423, 2001
2342001
A systematic evaluation of the spherical model accuracy in EEG dipole localization
B Yvert, O Bertrand, M Thevenet, JF Echallier, J Pernier
Electroencephalography and clinical neurophysiology 102 (5), 452-459, 1997
1251997
Localization of human supratemporal auditory areas from intracerebral auditory evoked potentials using distributed source models
B Yvert, C Fischer, O Bertrand, J Pernier
Neuroimage 28 (1), 140-153, 2005
1152005
3D-nanostructured boron-doped diamond for microelectrode array neural interfacing
G Piret, C Hébert, JP Mazellier, L Rousseau, E Scorsone, M Cottance, ...
Biomaterials 53, 173-183, 2015
902015
An evaluation of dipole reconstruction accuracy with spherical and realistic head models in MEG
A Crouzeix, B Yvert, O Bertrand, J Pernier
Clinical Neurophysiology 110 (12), 2176-2188, 1999
891999
Multiple spontaneous rhythmic activity patterns generated by the embryonic mouse spinal cord occur within a specific developmental time window
B Yvert, P Branchereau, P Meyrand
Journal of neurophysiology 91 (5), 2101-2109, 2004
802004
Real-time biomimetic central pattern generators in an FPGA for hybrid experiments
M Ambroise, T Levi, S Joucla, B Yvert, S Saïghi
Frontiers in neuroscience 7, 215, 2013
782013
Human lateral geniculate nucleus and visual cortex respond to screen flicker
P Krolak‐Salmon, MA Hénaff, C Tallon‐Baudry, B Yvert, M Guénot, ...
Annals of Neurology: Official Journal of the American Neurological …, 2003
772003
BioMEA™: A versatile high-density 3D microelectrode array system using integrated electronics
G Charvet, L Rousseau, O Billoint, S Gharbi, JP Rostaing, S Joucla, ...
Biosensors and Bioelectronics 25 (8), 1889-1896, 2010
712010
Nanostructuration strategies to enhance microelectrode array (MEA) performance for neuronal recording and stimulation
M Heim, B Yvert, A Kuhn
Journal of Physiology-Paris 106 (3-4), 137-145, 2012
682012
Improved forward EEG calculations using local mesh refinement of realistic head geometries
B Yvert, O Bertrand, JF Echallier, J Pernier
Electroencephalography and clinical Neurophysiology 95 (5), 381-392, 1995
681995
Modeling extracellular electrical neural stimulation: from basic understanding to MEA-based applications
S Joucla, B Yvert
Journal of Physiology-Paris 106 (3-4), 146-158, 2012
672012
3D shaped mechanically flexible diamond microelectrode arrays for eye implant applications: The MEDINAS project
P Bergonzo, A Bongrain, E Scorsone, A Bendali, L Rousseau, ...
Irbm 32 (2), 91-94, 2011
572011
Improved focalization of electrical microstimulation using microelectrode arrays: a modeling study
S Joucla, B Yvert
PloS one 4 (3), e4828, 2009
572009
A new 3-D finite-element model based on thin-film approximation for microelectrode array recording of extracellular action potential
C Moulin, A Glière, D Barbier, S Joucla, B Yvert, P Mailley, R Guillemaud
IEEE Transactions on Biomedical Engineering 55 (2), 683-692, 2008
562008
Improved dipole localization using local mesh refinement of realistic head geometries: an EEG simulation study
B Yvert, O Bertrand, JF Echallier, J Pernier
Electroencephalography and clinical Neurophysiology 99 (1), 79-89, 1996
541996
Three-dimensional electrode arrays for retinal prostheses: modeling, geometry optimization and experimental validation
M Djilas, C Oles, H Lorach, A Bendali, J Degardin, E Dubus, ...
Journal of neural engineering 8 (4), 046020, 2011
532011
Combined macro-/mesoporous microelectrode arrays for low-noise extracellular recording of neural networks
M Heim, L Rousseau, S Reculusa, V Urbanova, C Mazzocco, S Joucla, ...
Journal of neurophysiology 108 (6), 1793-1803, 2012
492012
Real-time control of an articulatory-based speech synthesizer for brain computer interfaces
F Bocquelet, T Hueber, L Girin, C Savariaux, B Yvert
PLoS computational biology 12 (11), e1005119, 2016
462016
The “mirror” estimate: an intuitive predictor of membrane polarization during extracellular stimulation
S Joucla, B Yvert
Biophysical journal 96 (9), 3495-3508, 2009
452009
El sistema no puede realizar la operación en estos momentos. Inténtalo de nuevo más tarde.
Artículos 1–20