Direct estimation of tracer‐kinetic parameter maps from highly undersampled brain dynamic contrast enhanced MRI
Y Guo, SG Lingala, Y Zhu, RM Lebel, KS Nayak
Magnetic resonance in medicine 78 (4), 1566-1578, 2017
392017
GOCART: GOlden-angle CArtesian randomized time-resolved 3D MRI
Y Zhu, Y Guo, SG Lingala, RM Lebel, M Law, KS Nayak
Magnetic resonance imaging 34 (7), 940-950, 2016
342016
Accelerated cardiac cine MRI using locally low rank and finite difference constraints
X Miao, SG Lingala, Y Guo, T Jao, M Usman, C Prieto, KS Nayak
Magnetic resonance imaging 34 (6), 707-714, 2016
322016
High‐resolution whole‐brain DCE‐MRI using constrained reconstruction: Prospective clinical evaluation in brain tumor patients
Y Guo, RM Lebel, Y Zhu, SG Lingala, MS Shiroishi, M Law, K Nayak
Medical physics 43 (5), 2013-2023, 2016
302016
Joint arterial input function and tracer kinetic parameter estimation from undersampled dynamic contrast‐enhanced MRI using a model consistency constraint
Y Guo, SG Lingala, Y Bliesener, RM Lebel, Y Zhu, KS Nayak
Magnetic resonance in medicine 79 (5), 2804-2815, 2018
122018
Communications system
G Sasvari, P Colleit
US Patent App. 10/203,392, 2004
112004
Accelerated DCE MRI using constrained reconstruction based on pharmaco-kinetic model dictionaries
SG Lingala, Y Guo, Y Zhu, S Barnes, RM Lebel, KS Nayak
Proceedings of the 23rd Annual Meeting of ISMRM, Toronto, Ontario, Abstract 1539, 2015
92015
Highly accelerated brain DCE MRI with direct estimation of pharmacokinetic parameter maps
Y Guo, Y Zhu, SG Lingala, RM Lebel, KS Nayak
Proceedings of the 23rd Annual Meeting of ISMRM, Toronto, Ontario, Abstract 1093, 2015
92015
The comprehensive contrast-enhanced neuro exam
RM Lebel, Y Guo, Y Zhu, SG Lingala, R Frayne, LB Andersen, J Easaw, ...
Proceedings 23th Annual Meeting of ISMRM, Toronto, Canada, 4456, 2015
92015
Evaluation of DCE-MRI data sampling, reconstruction and model fitting using digital brain phantom
Y Zhu, Y Guo, SG Lingala, S Barnes, RM Lebel, M Law, KS Nayak
Proc Int Soc Magn Reson Med 3070, 2015
82015
Tracer kinetic models as temporal constraints during brain tumor DCE‐MRI reconstruction
SG Lingala, Y Guo, Y Bliesener, Y Zhu, RM Lebel, M Law, KS Nayak
Medical physics 47 (1), 37-51, 2020
52020
Randomized golden ratio sampling for highly accelerated dynamic imaging
Y Zhu, Y Guo, RM Lebel, M Law, KS Nayak
Proc. ISMRM 22nd Sci. Sess, 4365, 2014
52014
Accuracy, uncertainty, and adaptability of automatic myocardial ASL segmentation using deep CNN
HP Do, Y Guo, AJ Yoon, KS Nayak
Magnetic resonance in medicine 83 (5), 1863-1874, 2020
32020
Accelerated cardiac cine using locally low rank and total variation constraints
X Miao, SG Lingala, Y Guo, T Jao, KS Nayak
Proceedings of the 23rd Annual Meeting, Toronto, Canada, 571, 2015
32015
Method for improved dynamic contrast enhanced imaging using tracer-kinetic models as constraints
KS Nayak, YI Guo, RM Lebel, Y Zhu, SG Lingala
US Patent App. 15/595,156, 2017
22017
Tracer kinetic models as temporal constraints during DCE-MRI reconstruction
S Goud Lingala, Y Guo, RM Lebel, Y Zhu, Y Bliesener, M Law, KS Nayak
arXiv e-prints, arXiv: 1707.07569, 2017
22017
High-resolution whole-brain dynamic contrast-enhanced MRI using compressed sensing
Y Guo, Y Zhu, LS Goud, RM Lebel, M Shiroishi
Biomedical optics & medical imaging. SPIE Newsroom, Bellingham, 2015
22015
Radiofrequency transmit calibration: A multi‐center evaluation of vendor‐provided radiofrequency transmit mapping methods
Y Bliesener, X Zhong, Y Guo, M Boss, R Bosca, H Laue, C Chung, K Sung, ...
Medical physics 46 (6), 2629-2637, 2019
12019
MRI Constrained Reconstruction Without Tuning Parameters Using ADMM and Morozov's Discrepency Principle
W Chen, Y Guo, Z Wu, K Nayak
ISMRM 23rd Annu. Meet. Exhib 3410, 2015
12015
Joint arterial input function and tracker kinetic parameter estimation from under-sampled DCE-MRI using a model consistency constraint
Y Guo, SG Lingala, Y Bliesener, RM Lebel, Y Zhu, KS Nayak
Magnetic resonance in medicine 79 (5), 2804, 2018
2018