Femoral head lag screw position for cephalomedullary nails: a biomechanical analysis PRT Kuzyk, R Zdero, S Shah, M Olsen, JP Waddell, EH Schemitsch Journal of orthopaedic trauma 26 (7), 414-421, 2012 | 178 | 2012 |
The biomechanics of locked plating for repairing proximal humerus fractures with or without medial cortical support J Lescheid, R Zdero, S Shah, PRT Kuzyk, EH Schemitsch Journal of Trauma and Acute Care Surgery 69 (5), 1235-1242, 2010 | 162 | 2010 |
Biomechanical properties of an intact, injured, repaired, and healed femur: an experimental and computational study H Ebrahimi, M Rabinovich, V Vuleta, D Zalcman, S Shah, A Dubov, K Roy, ... Journal of the mechanical behavior of biomedical materials 16, 121-135, 2012 | 101 | 2012 |
The biomechanics of plate fixation of periprosthetic femoral fractures near the tip of a total hip implant: cables, screws, or both? S Shah, SYR Kim, A Dubov, EH Schemitsch, H Bougherara, R Zdero Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2011 | 99 | 2011 |
A preliminary biomechanical study of a novel carbon–fibre hip implant versus standard metallic hip implants H Bougherara, R Zdero, A Dubov, S Shah, S Khurshid, EH Schemitsch Medical engineering & physics 33 (1), 121-128, 2011 | 79 | 2011 |
The biomechanics of plate repair of periprosthetic femur fractures near the tip of a total hip implant: the effect of cable-screw position A Dubov, SYR Kim, S Shah, EH Schemitsch, R Zdero, H Bougherara Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2011 | 74 | 2011 |
The biomechanics of the T2 femoral nailing system: a comparison of synthetic femurs with finite element analysis H Bougherara, R Zdero, M Miric, S Shah, M Hardisty, P Zalzal, ... Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2009 | 68 | 2009 |
A biomechanical assessment of modular and monoblock revision hip implants using FE analysis and strain gage measurements H Bougherara, R Zdero, S Shah, M Miric, M Papini, P Zalzal, ... Journal of orthopaedic surgery and research 5, 1-12, 2010 | 63 | 2010 |
Experimental methods in orthopaedic biomechanics R Zdero Academic Press, 2016 | 61 | 2016 |
The effect of cortex thickness on intact femur biomechanics: a comparison of finite element analysis with synthetic femurs R Zdero, H Bougherara, A Dubov, S Shah, P Zalzal, A Mahfud, ... Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2010 | 58 | 2010 |
The biomechanics of a validated finite element model of stress shielding in a novel hybrid total knee replacement H Bougherara, R Zdero, Z Mahboob, A Dubov, S Shah, EH Schemitsch Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2010 | 50 | 2010 |
The biomechanical effect of changes in cancellous bone density on synthetic femur behaviour B Nicayenzi, S Shah, EH Schemitsch, H Bougherara, R Zdero Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2011 | 46 | 2011 |
A biomechanical comparison of static versus dynamic lag screw modes for cephalomedullary nails used to fix unstable peritrochanteric fractures PRT Kuzyk, S Shah, R Zdero, M Olsen, JP Waddell, EH Schemitsch Journal of Trauma and Acute Care Surgery 72 (2), E65-E70, 2012 | 37 | 2012 |
Biomechanical stress maps of an artificial femur obtained using a new infrared thermography technique validated by strain gages S Shah, H Bougherara, EH Schemitsch, R Zdero Medical engineering & physics 34 (10), 1496-1502, 2012 | 35 | 2012 |
Biomechanical analysis using FEA and experiments of metal plate and bone strut repair of a femur midshaft segmental defect J Coquim, J Clemenzi, M Salahi, A Sherif, P Tavakkoli Avval, S Shah, ... BioMed research international 2018, 2018 | 33 | 2018 |
The effect of load application rate on the biomechanics of synthetic femurs R Zdero, S Shah, M Mosli, EH Schemitsch Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2010 | 31 | 2010 |
A preliminary biomechanical assessment of a polymer composite hip implant using an infrared thermography technique validated by strain gage measurements H Bougherara, E Rahim, S Shah, A Dubov, EH Schemitsch, R Zdero | 27 | 2011 |
The biomechanics of three different fracture fixation implants for distal femur repair in the presence of a tumor-like defect S Ahmadi, S Shah, JS Wunder, EH Schemitsch, PC Ferguson, R Zdero Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2013 | 24 | 2013 |
Biomechanical analysis using infrared thermography of a traditional metal plate versus a carbon fibre/epoxy plate for Vancouver B1 femur fractures FS Siddiqui, S Shah, B Nicayenzi, EH Schemitsch, R Zdero, ... Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2014 | 21 | 2014 |
The biomechanical effect of proximal tumor defect location on femur pathological fractures R Sivasundaram, S Shah, S Ahmadi, JS Wunder, EH Schemitsch, ... Journal of Orthopaedic Trauma 27 (8), e174-e180, 2013 | 18 | 2013 |