Seguir
Sajendra Nithiananthan
Sajendra Nithiananthan
Johns Hopkins University
Dirección de correo verificada de intel.com
Título
Citado por
Citado por
Año
Mobile C‐arm cone‐beam CT for guidance of spine surgery: image quality, radiation dose, and integration with interventional guidance
S Schafer, S Nithiananthan, DJ Mirota, A Uneri, JW Stayman, W Zbijewski, ...
Medical physics 38 (8), 4563-4574, 2011
1432011
Demons deformable registration for CBCT‐guided procedures in the head and neck: convergence and accuracy
S Nithiananthan, KK Brock, MJ Daly, H Chan, JC Irish, JH Siewerdsen
Medical physics 36 (10), 4755-4764, 2009
1292009
Demons deformable registration of CT and cone‐beam CT using an iterative intensity matching approach
S Nithiananthan, S Schafer, A Uneri, DJ Mirota, JW Stayman, W Zbijewski, ...
Medical physics 38 (4), 1785-1798, 2011
1132011
Extra‐dimensional Demons: a method for incorporating missing tissue in deformable image registration
S Nithiananthan, S Schafer, DJ Mirota, JW Stayman, W Zbijewski, DD Reh, ...
Medical physics 39 (9), 5718-5731, 2012
732012
Deformable registration of the inflated and deflated lung in cone‐beam CT‐guided thoracic surgery: Initial investigation of a combined model‐and image‐driven approach
A Uneri, S Nithiananthan, S Schafer, Y Otake, JW Stayman, G Kleinszig, ...
Medical physics 40 (1), 017501, 2013
582013
Intraoperative use of cone-beam computed tomography in a cadaveric ossified cochlea model
E Barker, K Trimble, H Chan, J Ramsden, S Nithiananthan, A James, ...
Otolaryngology—Head and Neck Surgery 140 (5), 697-702, 2009
542009
TREK: an integrated system architecture for intraoperative cone-beam CT-guided surgery
A Uneri, S Schafer, DJ Mirota, S Nithiananthan, Y Otake, RH Taylor, ...
International journal of computer assisted radiology and surgery 7, 159-173, 2012
482012
Evaluation of a system for high-accuracy 3D image-based registration of endoscopic video to C-arm cone-beam CT for image-guided skull base surgery
DJ Mirota, A Uneri, S Schafer, S Nithiananthan, DD Reh, M Ishii, GL Gallia, ...
IEEE transactions on medical imaging 32 (7), 1215-1226, 2013
452013
High-performance intraoperative cone-beam CT on a mobile C-arm: an integrated system for guidance of head and neck surgery
JH Siewerdsen, MJ Daly, H Chan, S Nithiananthan, N Hamming, ...
Medical Imaging 2009: Visualization, Image-Guided Procedures, and Modeling …, 2009
432009
An on-board surgical tracking and video augmentation system for C-arm image guidance
S Reaungamornrat, Y Otake, A Uneri, S Schafer, DJ Mirota, ...
International journal of computer assisted radiology and surgery 7, 647-665, 2012
422012
Fusion of intraoperative cone-beam CT and endoscopic video for image-guided procedures
MJ Daly, H Chan, E Prisman, A Vescan, S Nithiananthan, J Qiu, ...
Medical Imaging 2010: Visualization, Image-Guided Procedures, and Modeling …, 2010
352010
Deformable image registration for cone-beam CT guided transoral robotic base-of-tongue surgery
S Reaungamornrat, WP Liu, AS Wang, Y Otake, S Nithiananthan, A Uneri, ...
Physics in Medicine & Biology 58 (14), 4951, 2013
292013
Clinical implementation of intraoperative cone-beam CT in head and neck surgery
MJ Daly, H Chan, S Nithiananthan, J Qiu, E Barker, G Bachar, BJ Dixon, ...
Medical Imaging 2011: Visualization, Image-Guided Procedures, and Modeling …, 2011
292011
Three‐dimensional tomosynthesis and cone‐beam computed tomography: An experimental study for fast, low‐dose intraoperative imaging technology for guidance of sinus and skull …
G Bachar, E Barker, S Nithiananthan, H Chan, MJ Daly, JC Irish, ...
The Laryngoscope 119 (3), 434-441, 2009
262009
High-accuracy 3D image-based registration of endoscopic video to C-arm cone-beam CT for image-guided skull base surgery
DJ Mirota, A Uneri, S Schafer, S Nithiananthan, DD Reh, GL Gallia, ...
Medical Imaging 2011: Visualization, Image-Guided Procedures, and Modeling …, 2011
252011
Intraoperative C‐arm cone‐beam computed tomography: Quantitative analysis of surgical performance in skull base surgery
S Lee, GL Gallia, DD Reh, S Schafer, A Uneri, DJ Mirota, S Nithiananthan, ...
The Laryngoscope 122 (9), 1925-1932, 2012
212012
Deformable registration for intra-operative cone-beam CT guidance of head and neck surgery
S Nithiananthan, KK Brock, JC Irish, JH Siewerdsen
2008 30th Annual International Conference of the IEEE Engineering in …, 2008
182008
Method and system for registering images
JH Siewerdsen, S Nithiananthan, DJ Mirota
US Patent 9,218,643, 2015
132015
High-performance C-arm cone-beam CT guidance of thoracic surgery
S Schafer, Y Otake, A Uneri, DJ Mirota, S Nithiananthan, JW Stayman, ...
Medical Imaging 2012: Image-Guided Procedures, Robotic Interventions, and …, 2012
122012
Visualization of anterior skull base defects with intraoperative cone‐beam CT
G Bachar, E Barker, H Chan, MJ Daly, S Nithiananthan, A Vescan, ...
Head & Neck: Journal for the Sciences and Specialties of the Head and Neck …, 2010
122010
El sistema no puede realizar la operación en estos momentos. Inténtalo de nuevo más tarde.
Artículos 1–20