Seguir
Jeffrey Gohean
Jeffrey Gohean
Windmill Cardiovascular Systems
Dirección de correo verificada de windmillcvs.com
Título
Citado por
Citado por
Año
Patient-specific isogeometric fluid–structure interaction analysis of thoracic aortic blood flow due to implantation of the Jarvik 2000 left ventricular assist device
Y Bazilevs, JR Gohean, TJR Hughes, RD Moser, Y Zhang
Computer Methods in Applied Mechanics and Engineering 198 (45-46), 3534-3550, 2009
4872009
Improved left ventricular unloading and circulatory support with synchronized pulsatile left ventricular assistance compared with continuous-flow left ventricular assistance in …
GV Letsou, TD Pate, JR Gohean, M Kurusz, RG Longoria, L Kaiser, ...
The Journal of thoracic and cardiovascular surgery 140 (5), 1181-1188, 2010
742010
Positive displacement pump system and method
T Pate, R Longoria, R Smalling, J Gohean
US Patent App. 11/773,740, 2008
542008
Magnetic ventricular connector
TD Pate, JR Gohean, RG Longoria, RW Smalling
US Patent 8,715,305, 2014
522014
Verification of a computational cardiovascular system model comparing the hemodynamics of a continuous flow to a synchronous valveless pulsatile flow left ventricular assist device
JR Gohean, MJ George, TD Pate, M Kurusz, RG Longoria, RW Smalling
ASAIO journal 59 (2), 107-116, 2013
382013
System and method for pump with deformable bearing surface
JR Gohean, TD Pate, RG Longoria, R Smalling
US Patent 8,167,593, 2012
342012
System and method for pump with deformable bearing surface
JR Gohean, TD Pate, RG Longoria, R Smalling
US Patent 8,167,593, 2012
342012
Scaling the low-shear pulsatile TORVAD for pediatric heart failure
JR Gohean, ER Larson, BH Hsi, M Kurusz, RW Smalling, RG Longoria
ASAIO Journal 63 (2), 198-206, 2017
302017
System and method for controlling pump
JR Gohean, TD Pate, RG Longoria, R Smalling
US Patent App. 13/929,501, 2014
292014
System and method for controlling pump
JR Gohean, TD Pate, RG Longoria, R Smalling
US Patent App. 13/929,501, 2014
292014
Comparative in vitro study of bileaflet and tilting disk valve behavior in the pulmonary position
J Gohean, R Figliola, T Camp, T McQuinn
252006
System and method for pump variable stroke
TD Pate, RG Longoria, R Smalling, JR Gohean
US Patent 8,386,040, 2013
232013
System and method for pump variable stroke
TD Pate, RG Longoria, R Smalling, JR Gohean
US Patent 8,386,040, 2013
232013
Preservation of native aortic valve flow and full hemodynamic support with the TORVAD using a computational model of the cardiovascular system
JR Gohean, MJ George, KW Chang, ER Larson, TD Pate, M Kurusz, ...
ASAIO Journal 61 (3), 259-265, 2015
222015
System and method for controlling pump
JR Gohean, TD Pate, RG Longoria, R Smalling
US Patent App. 12/425,042, 2010
182010
Estimation of systemic vascular resistance using built-in sensing from an implanted left ventricular assist device
ES Rapp, SR Pawar, JR Gohean, ER Larson, RW Smalling, RG Longoria
Journal of Engineering and Science in Medical Diagnostics and Therapy 2 (4 …, 2019
92019
Positive displacement pump system and method with rotating valve
TD Pate, RG Longoria, R Smalling, JR Gohean
US Patent 8,366,401, 2013
72013
Positive displacement pump system and method with rotating valve
TD Pate, RG Longoria, R Smalling, JR Gohean
US Patent 8,366,401, 2013
72013
A closed-loop multi-scale model of the cardiovascular system for evaluation of ventricular assist devices
JR Gohean
University of Texas at Austin, 2007
72007
Hierarchical control of a two-piston toroidal blood pump
JR Gohean
The University of Texas at Austin, 2019
52019
El sistema no puede realizar la operación en estos momentos. Inténtalo de nuevo más tarde.
Artículos 1–20