Follow
Oline Vinter Olesen
Oline Vinter Olesen
PhD in Medical Image Analysis, Technical University of Denmark
Verified email at dtu.dk - Homepage
Title
Cited by
Cited by
Year
Motion tracking for medical imaging: a nonvisible structured light tracking approach
OV Olesen, RR Paulsen, L Hojgaard, B Roed, R Larsen
IEEE transactions on medical imaging 31 (1), 79-87, 2011
1162011
List-Mode PET Motion Correction Using Markerless Head Tracking: Proof-of-Concept With Scans of Human Subject
O Olesen, J Sullivan, T Mulnix, R Paulsen, L Højgaard, B Roed, R Carson, ...
Medical Imaging, IEEE Transactions on 32 (2), 200-209, 2013
752013
Spatial resolution of the HRRT PET scanner using 3D-OSEM PSF reconstruction
OV Olesen, M Sibomana, SH Keller, F Andersen, J Jensen, S Holm, ...
2009 IEEE nuclear science symposium conference record (NSS/MIC), 3789-3790, 2009
582009
Methods for motion correction evaluation using 18F-FDG human brain scans on a high-resolution PET scanner
SH Keller, M Sibomana, OV Olesen, C Svarer, S Holm, FL Andersen, ...
Journal of Nuclear Medicine 53 (3), 495-504, 2012
532012
Markerless motion tracking and correction for PET, MRI, and simultaneous PET/MRI
JM Slipsager, AH Ellegaard, SL Glimberg, RR Paulsen, MD Tisdall, ...
Plos one 14 (4), e0215524, 2019
372019
Motion tracking in narrow spaces: a structured light approach
OV Olesen, RR Paulsen, L Højgaard, B Roed, R Larsen
International Conference on Medical Image Computing and Computer-Assisted …, 2010
342010
Quantifying the financial savings of motion correction in brain MRI: a model‐based estimate of the costs arising from patient head motion and potential savings from …
JM Slipsager, SL Glimberg, J Søgaard, RR Paulsen, HH Johannesen, ...
Journal of Magnetic Resonance Imaging 52 (3), 731-738, 2020
322020
Accurate and simple calibration of DLP projector systems
J Wilm, OV Olesen, R Larsen
Emerging Digital Micromirror Device Based Systems and Applications VI 8979 …, 2014
262014
Structured light 3D tracking system for measuring motions in PET brain imaging
OV Olesen, MR Jørgensen, RR Paulsen, L Højgaard, B Roed, R Larsen
Medical Imaging 2010: Visualization, Image-Guided Procedures, and Modeling …, 2010
222010
Comparison of prospective and retrospective motion correction in 3D‐encoded neuroanatomical MRI
JM Slipsager, SL Glimberg, L Højgaard, RR Paulsen, P Wighton, ...
Magnetic resonance in medicine 87 (2), 629-645, 2022
192022
Apparatus and method for motion tracking in brain imaging
OV Olesen, R Larsen, RR Paulsen, L Højgaard
US Patent 10,542,913, 2020
192020
Hybrid PET/MRI imaging in healthy unsedated newborn infants with quantitative rCBF measurements using 15O-water PET
JB Andersen, U Lindberg, OV Olesen, D Benoit, CN Ladefoged, ...
Journal of Cerebral Blood Flow & Metabolism 39 (5), 782-793, 2019
192019
Prospective motion correction for diffusion weighted EPI of the brain using an optical markerless tracker
J Berglund, A van Niekerk, H Rydén, T Sprenger, E Avventi, O Norbeck, ...
Magnetic Resonance in Medicine 85 (3), 1427-1440, 2021
172021
SLStudio: Open-source framework for real-time structured light
J Wilm, OV Olesen, R Larsen
2014 4th International Conference on Image Processing Theory, Tools and …, 2014
152014
Innovations in pet/ct
TL Klausen, SH Keller, OV Olesen, M Aznar, FL Andersen
The quarterly journal of nuclear medicine and molecular imaging: official …, 2012
132012
Real Time MRI motion correction with markerless tracking
C Benjaminsen, RR Jensen, P Wighton, MD Tisdall, HH Johannesen, ...
ISMRM 2016 Annual Meeting & Exhibition, 2017
112017
New attenuation correction for the HRRT using transmission scatter correction and total variation regularization
M Sibomana, SH Keller, C Svarer, OV Olesen, F Andersen, S Holm, ...
2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC), 3284-3286, 2009
102009
An MRI compatible surface scanner
OV Olesen, J Wilm, A Van der Kouwe, RR Jensen, R Larsen, LL Wald
ISMRM Scientific Workshop: Motion Correction in MRI, 2015
92015
A movable phantom design for quantitative evaluation of motion correction studies on high resolution PET scanners
OV Olesen, C Svarer, M Sibomana, SH Keller, S Holm, JA Jensen, ...
IEEE Transactions on Nuclear Science 57 (3), 1116-1124, 2010
92010
Real time surface registration for PET motion tracking
J Wilm, OV Olesen, RR Paulsen, L Højgaard, B Roed, R Larsen
Image Analysis: 17th Scandinavian Conference, SCIA 2011, Ystad, Sweden, May …, 2011
82011
The system can't perform the operation now. Try again later.
Articles 1–20