Alejandro Laguna Sanz
Alejandro Laguna Sanz
Centro de Investigación Biomédica en red (CIBER)
Dirección de correo verificada de upvnet.upv.es
TítuloCitado porAño
Evaluation of a novel continuous glucose monitoring-based method for mealtime insulin dosing—the iBolus—in subjects with type 1 diabetes using continuous subcutaneous insulin …
P Rossetti, FJ Ampudia-Blasco, A Laguna, A Revert, J Vehì, JF Ascaso, ...
Diabetes technology & therapeutics 14 (11), 1043-1052, 2012
222012
Experimental blood glucose interval identification of patients with type 1 diabetes
AJ Laguna, P Rossetti, FJ Ampudia-Blasco, J Vehí, J Bondia
Journal of Process Control 24 (1), 171-181, 2014
132014
Optimal design for individual model identification based on ambulatory continuous glucose monitoring in patients with type 1 diabetes
AJ Laguna, P Rossetti, FJ Ampudia-Blasco, J Vehí, J Bondia
IET Digital Library, 2010
102010
An enhanced model predictive control for the artificial pancreas using a confidence index based on residual analysis of past predictions
AJ Laguna Sanz, FJ Doyle III, E Dassau
Journal of diabetes science and technology 11 (3), 537-544, 2017
82017
Identification of intra-patient variability in the postprandial response of patients with type 1 diabetes
AJ Laguna, P Rossetti, FJ Ampudia-Blasco, J Vehí, J Bondia
Biomedical Signal Processing and Control 12, 39-46, 2014
82014
Evaluation of an artificial pancreas with enhanced model predictive control and a glucose prediction trust index with unannounced exercise
JE Pinsker, AJ Laguna Sanz, JB Lee, MM Church, C Andre, LE Lindsey, ...
Diabetes technology & therapeutics 20 (7), 455-464, 2018
72018
Design and clinical evaluation of a novel low-glucose prediction algorithm with mini-dose stable glucagon delivery in post-bariatric hypoglycemia
AJ Laguna Sanz, CM Mulla, KM Fowler, E Cloutier, AB Goldfine, ...
Diabetes technology & therapeutics 20 (2), 127-139, 2018
52018
Postprandial performance of Dexcom® SEVEN® PLUS and Medtronic® Paradigm® Veo™: modeling and statistical analysis
AJ Laguna, P Rossetti, FJ Ampudia-Blasco, J Vehí, J Bondia
Biomedical Signal Processing and Control 10, 322-331, 2014
52014
Identification of intra-patient variability in the postprandial response of patients with type 1 diabetes
AJ Laguna, P Rossetti, FJ Ampudia-Blasco, J Vehí, J Bondia
IFAC Proceedings Volumes 45 (18), 34-39, 2012
12012
On the use of hard/soft specifications to deal with intra-patient variability in postprandial glucose control in type 1 diabetes
J Bondia, AJ Laguna, P Rossetti, FJ Ampudia-Blasco, J Vehí
IFAC Proceedings Volumes 44 (1), 8347-8353, 2011
12011
Threshold-based insulin pump-interruption for reduction of hypoglycemia
P Kardas, P Beck, S Bromuri, F Chiarugi, M Enzmann, B Höll, O Keller, ...
Diabetes Technology & Therapeutics 16 (S1), A-1-A-162, 2014
2014
A Novel Strategy for Non-Empirical Calculation of Prandial Insulin Bolus Based on Continuous Glucose Monitoring (CGM) in Subjects with Type 1 Diabetes (T1DM) Treated with …
P Rossetti, F Javier Ampudia-Blasco, A Laguna, A Revert, J Vehi, R Calm, ...
DIABETES 60, A589-A589, 2011
2011
A meta-analysis of cytokines in Major Depression
E Abbink, E Engwerda, C Tack, B de Galan, SA Amiel, T Danne, ...
Diabetes Technology & Therapeutics 13 (2), 173-293, 2011
2011
El sistema no puede realizar la operación en estos momentos. Inténtalo de nuevo más tarde.
Artículos 1–13