Seguir
Juan Pablo Martínez
Juan Pablo Martínez
Instituto de Investigación en Ingeniería de Aragón. Universidad de Zaragoza. Departamento de
Dirección de correo verificada de unizar.es
Título
Citado por
Citado por
Año
A wavelet-based ECG delineator: evaluation on standard databases
JP Martínez, R Almeida, S Olmos, AP Rocha, P Laguna
IEEE Transactions on biomedical engineering 51 (4), 570-581, 2004
18992004
Microvolt T-wave alternans: physiological basis, methods of measurement, and clinical utility—consensus guideline by International Society for Holter and Noninvasive …
RL Verrier, T Klingenheben, M Malik, N El-Sherif, DV Exner, ...
Journal of the American College of Cardiology 58 (13), 1309-1324, 2011
4542011
Heartbeat classification using feature selection driven by database generalization criteria
M Llamedo, JP Martínez
IEEE Transactions on Biomedical Engineering 58 (3), 616-625, 2011
4082011
Optimization of ECG classification by means of feature selection
T Mar, S Zaunseder, JP Martínez, M Llamedo, R Poll
IEEE transactions on Biomedical Engineering 58 (8), 2168-2177, 2011
2842011
Methodological principles of T wave alternans analysis: a unified framework
JP Martínez, S Olmos
IEEE Transactions on Biomedical Engineering 52 (4), 599-613, 2005
2592005
Computational techniques for ECG analysis and interpretation in light of their contribution to medical advances
A Lyon, A Mincholé, JP Martínez, P Laguna, B Rodriguez
Journal of The Royal Society Interface 15 (138), 20170821, 2018
1512018
An automatic patient-adapted ECG heartbeat classifier allowing expert assistance
M Llamedo, JP Martínez
IEEE Transactions on Biomedical Engineering 59 (8), 2312-2320, 2012
1222012
Characterization of repolarization alternans during ischemia: time-course and spatial analysis
JP Martínez, S Olmos, G Wagner, P Laguna
IEEE Transactions on Biomedical Engineering 53 (4), 701-711, 2006
1072006
Multilead analysis of T-wave alternans in the ECG using principal component analysis
V Monasterio, P Laguna, JP Martinez
IEEE Transactions on Biomedical Engineering 56 (7), 1880-1890, 2009
982009
Evaluation of a wavelet-based ECG waveform detector on the QT database
JP Martinez, S Olmos, P Laguna
Computers in Cardiology 2000. Vol. 27 (Cat. 00CH37163), 81-84, 2000
772000
QT variability and HRV interactions in ECG: quantification and reliability
R Almeida, S Gouveia, AP Rocha, E Pueyo, JP Martínez, P Laguna
IEEE Transactions on Biomedical Engineering 53 (7), 1317-1329, 2006
752006
Average T-wave alternans activity in ambulatory ECG records predicts sudden cardiac death in patients with chronic heart failure
V Monasterio, P Laguna, I Cygankiewicz, R Vázquez, A Bayés-Genís, ...
Heart Rhythm 9 (3), 383-389, 2012
612012
Multilead ECG delineation using spatially projected leads from wavelet transform loops
R Almeida, JP MartÍnez, AP Rocha, P Laguna
IEEE transactions on biomedical engineering 56 (8), 1996-2005, 2009
612009
A multilead scheme based on periodic component analysis for T-wave alternans analysis in the ECG
V Monasterio, GD Clifford, P Laguna, JP MARTInez
Annals of biomedical engineering 38 (8), 2532-2541, 2010
602010
Heart rate turbulence analysis based on photoplethysmography
E Gil, P Laguna, JP Martínez, O Barquero-Pérez, A García-Alberola, ...
IEEE Transactions on Biomedical Engineering 60 (11), 3149-3155, 2013
582013
Cardiac repolarization analysis using the surface electrocardiogram
E Pueyo, JP Martínez, P Laguna
Philosophical Transactions of the Royal Society A: Mathematical, Physical …, 2009
582009
An ECG classification model based on multilead wavelet transform features
ML Soria, JP Martinez
Computers in Cardiology, 2007, 105-108, 2007
532007
Analysis of multidomain features for ECG classification
ML Soria, JP Martínez
Computers in Cardiology, 2009, 561-564, 2009
462009
A robust T wave alternans detector based on the GLRT for Laplacian noise distribution
JP Martínez, S Olmos
Computers in Cardiology, 2002, 677-680, 2002
462002
Techniques for ventricular repolarization instability assessment from the ECG
P Laguna, JPM Cortés, E Pueyo
Proceedings of the IEEE 104 (2), 392-415, 2016
442016
El sistema no puede realizar la operación en estos momentos. Inténtalo de nuevo más tarde.
Artículos 1–20