First Prize: Characterization of Renal Ischemia Using DLP® Hyperspectral Imaging: A Pilot Study Comparing Artery-Only Occlusion Versus Artery and Vein Occlusion CR Tracy, JD Terrell, RP Francis, EF Wehner, J Smith, M Litorja, ... Journal of endourology 24 (3), 321-325, 2010 | 61 | 2010 |
Active DLP hyperspectral illumination: a noninvasive, in vivo, system characterization visualizing tissue oxygenation at near video rates KJ Zuzak, RP Francis, EF Wehner, M Litorja, JA Cadeddu, EH Livingston Analytical chemistry 83 (19), 7424-7430, 2011 | 47 | 2011 |
First place: Renal oxygenation during robot-assisted laparoscopic partial nephrectomy: Characterization using laparoscopic digital light processing hyperspectral imaging EO Olweny, S Faddegon, SL Best, N Jackson, EF Wehner, YK Tan, ... Journal of endourology 27 (3), 265-269, 2013 | 38 | 2013 |
DLP hyperspectral imaging for surgical and clinical utility KJ Zuzak, RP Francis, EF Wehner, J Smith, M Litorja, DW Allen, C Tracy, ... Emerging Digital Micromirror Device Based Systems and Applications 7210, 46-54, 2009 | 28 | 2009 |
Renal oxygenation measurement during partial nephrectomy using hyperspectral imaging may predict acute postoperative renal function SL Best, A Thapa, N Jackson, E Olweny, M Holzer, S Park, E Wehner, ... Journal of endourology 27 (8), 1037-1040, 2013 | 26 | 2013 |
Hyperspectral imaging utilizing LCTF and DLP technology for surgical and clinical applications KJ Zuzak, RP Francis, EF Wehner, J Smith, M Litorja, DW Allen, C Tracy, ... Design and Quality for Biomedical Technologies II 7170, 71-79, 2009 | 23 | 2009 |
NIR DLP hyperspectral imaging system for medical applications E Wehner, A Thapa, E Livingston, K Zuzak Emerging Digital Micromirror Device Based Systems and Applications III 7932 …, 2011 | 13 | 2011 |
The robustness of DLP hyperspectral imaging for clinical and surgical utility KJ Zuzak, E Wehner, S Rao, M Litorja, DW Allen, M Singer, G Purdue, ... Emerging Digital Micromirror Device Based Systems and Applications II 7596 …, 2010 | 11 | 2010 |
Hyperspectral image projection of a pig kidney for the evaluation of imagers used for oximetry DW Allen, S Maxwell, JP Rice, R Chang, M Litorja, J Hwang, J Cadeddu, ... Optical Diagnostics and Sensing XI: Toward Point-of-Care Diagnostics; and …, 2011 | 7 | 2011 |
Assessment of renal oxygenation during partial nephrectomy using DLP hyperspectral imaging SL Best, A Thapa, MS Holzer, N Jackson, SA Mir, CJ Donnally, E Wehner, ... Emerging Digital Micromirror Device Based Systems and Applications III 7932 …, 2011 | 5 | 2011 |
Visible to NIR DLP hyperspectral imaging system for surgical utility using inherent chromophores and fluorescent probes ML Mangum, M Saint-Cyr, EF Wehner, A Thapa, E Livingston, KJ Zuzak Emerging Digital Micromirror Device Based Systems and Applications III 7932 …, 2011 | 4 | 2011 |
Hyperspectral image segmentation of the common bile duct D Samarov, E Wehner, R Schwarz, K Zuzak, E Livingston Emerging Digital Micromirror Device Based Systems and Applications V 8618, 60-67, 2013 | 2 | 2013 |
Calibration and validation scheme for in vivo spectroscopic imaging of tissue oxygenation M Litorja, R Chang, J Hwang, DW Allen, K Zuzak, E Wehner, S Best, ... Oxygen Transport to Tissue XXXIV, 123-129, 2013 | 2 | 2013 |
Renal oxygenation during robotic-assisted laparoscopic partial nephrectomy; characterization using laparoscopic digital light processing (DLP (R)) hyperspectral imaging EO Olweny, S Faddegon, SL Best, N Jackson, EF Wehner, YK Tan, ... Journal of Endourology 26, A3-A3, 2012 | 2 | 2012 |
An examination of spectral diversity of medical scenes for hyperspectral projection DW Allen, JP Rice, E Wehner, R McMahon, E Livingston, J White, ... Emerging Digital Micromirror Device Based Systems and Applications III 7932 …, 2011 | 2 | 2011 |
Characterization of renal ischemia using Dlp (R) Hyperspectral imaging: a comparison of Artery-Only occlusion (AO) versus Artery and Vein occlusion (AV) C Tracy, R Francis, E Wehner, J Smith, J Cadeddu, K Zuzak JOURNAL OF ENDOUROLOGY 23, A131-A132, 2009 | 2* | 2009 |
Spectral light source distribution variations to enhance discrimination of the common bile duct from surroundings in reflectance hyperspectral images M Litorja, M Fein, E Wehner, R Schwarz, K Zuzak, E Livingston Emerging Digital Micromirror Device Based Systems and Applications V 8618, 38-45, 2013 | 1 | 2013 |
Evaluation of a novel laparoscopic camera for characterization of renal ischemia in a porcine model using digital light processing (DLP) hyperspectral imaging EO Olweny, YK Tan, S Faddegon, N Jackson, EF Wehner, SL Best, ... Emerging Digital Micromirror Device Based Systems and Applications IV 8254 …, 2012 | 1 | 2012 |
Renal oxygenation measurement during partial nephrectomy using DLP® hyperspectral imaging predicts post-operative renal function MS Holzer, SL Best, N Jackson, A Thapa, SA Mir, CJ Donnally, S Rao, ... World Congress of Endourology meeting, Chicago, IL, 2010 | 1 | 2010 |
722 CHARACTERIZATION OF RENAL ISCHEMIA USING DLP® HYPERSPECTRAL IMAGING: A COMPARISON OF ARTERY-ONLY OCCLUSION (AO) VERSUS ARTERY AND VEIN OCCLUSION (AV) CR Tracy, JD Terrell, RP Francis, EF Wehner, J Smith, M Litorja, ... The Journal of urology 183 (4S), e281-e281, 2010 | 1 | 2010 |